page 7
6. Wiring.
WARNING
: Turn off circuit breakers to current
fixture from breaker panel and be sure switch is
turned to the OFF position.
CAUTION
:
Be sure outlet box is properly
grounded and that a ground wire (
GREEN
or
Bare) is present.
Make sure all electrical connections comply with
Local Codes or Ordinances and the National
Electrical Code.
If you are unfamiliar with electrical wiring or if
the house/building wires are different colors
than those referred to in the instructions below,
please use a qualified electrician.
Note
:
Excess lead wire length from the fan can
be cut to the desired length and then stripped.
When downrod is secured in place on the
hanging bracket, electrical wiring can be made
as follows:
Connect
BLACK
and
BLUE
wire from fan to
BLACK
wire from ceiling with wire connector
provided.
Connect
WHITE
wire from fan to
WHITE
wire
from ceiling with wire connector provided.
Connect all
GROUND
(
GREEN
) wires together
from fan to
BARE
/
GREEN
wire from ceiling
with wire connector provided.
Since this fan does not come with a light kit,
you will need to cap off the
BLUE
wire with a
wire connector (as shown with arrow in
diagram). [
Note
: If you elect to purchase a light
kit for the fan, the
BLUE
wire from the fan must
be connected to the
BLACK
wire from the
ceiling instead.]
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
This fan is remote control adaptable (remote
control sold separately).
(wiring for fan)
wire
connector
black
black
white
white
blue
black supply wire
ground
(green
or bare)
white supply wire
from ceiling
from fan
ground
(green or bare)
*