SAFETY TIPS.

page 2

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit panel 

before you begin the fan installation or before servicing the fan or installing accessories.

1.         

READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND 

SAVE THESE INSTRUCTIONS.

CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.

2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and 

ANSI/NFPA 70-1999.  If you are unfamiliar with electrical wiring or if the house/building wires are different 
colors than those referred to in the instructions, please use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at least 

seven (7) feet (2.13 meters) of clearance between the floor and the fan blade tips.  The fan should be 
mounted so that the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or other 
upright structures.

4.         The outlet box and ceiling support joist used must be securely mounted and capable of supporting at least 35 

pounds (16 kilograms).  The outlet box must be supported directly by the building structure.  Use only CETL 
or CUL in Canada or ETL or UL in USA listed outlet boxes marked "FOR FAN SUPPORT."

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked "Acceptable 

for Fan Support of 15.9 kg (35 lb) or less," and use the mounting screws provided with the outlet box.  Most outlet 
boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be 
replaced.  Consult a qualified electrician if in doubt.

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are 

designed to accept only one 12 gauge house wire and two lead wires from the fan. If your house wire is larger than 12 
gauge or there is more than one house wire to connect to the corresponding fan lead wires, consult an electrician for 
the proper size wire connectors to use.

5.         Electrical diagrams are for reference only.  Light kits that are not packed with the fan must be CETL or CUL in 

Canada or ETL or UL in USA listed and marked suitable for use with the model fan you are installing.  
Switches must be CETL or CUL in Canada or ETL or UL in USA general use switches.  Refer to the instructions 
packaged with the light kits and switches for proper assembly.

6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up into 

the outlet box.  The wires should be spread apart with the grounded conductor and the 
equipment-grounding conductor on opposite sides of the outlet box.

WARNING

:  To reduce the risk of electrical shock or fire, do not use this fan with any solid state speed control device 

or control fan speed with a full range dimmer switch.  [Using a full range dimmer switch to control fan speed will 
cause a loud humming noise from fan.]  (

Note

: This fan 

is

 suitable for use with remote control.)

8.        Do not operate the reverse switch until fan has come to a complete stop.
9.        Do not insert anything between the fan blades while they are rotating.

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation.  Do 

not insert objects into the path of the blades.

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or 

cleaning the fan.

10.      Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth 

will be suitable for most cleaning.

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts OTHER than 

those provided with this fan will void the warranty.

WARNING

:  

This fan MUST be installed with the safety cable provided with the fan.  Failure to use the safety cable 

provided may result in personal injury, damage to the fan or damage to other property.

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all possible 

conditions and situations that may occur.  It must be understood that common sense and caution are necessary 
factors in the installation and operation of this fan.

Содержание Moto MOT52

Страница 1: ...tallation Preparation pg 4 Hanging Bracket Installation pg 4 Fan Assembly pgs 5 6 Wiring pg 7 Canopy Assembly pg 8 Blade Assembly pg 8 Switch Housing Assembly pg 9 Testing Your Fan pg 9 Troubleshooting pg 10 Parts Replacement pg 10 Warranty pg 10 net weight of fan 13 64 lb 6 20 kg page 1 PRINTED IN CHINA READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE Moto ...

Страница 2: ...lectrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CETL or CUL in Canada or ETL or UL in USA listed and marked suitable for use with the model fan you are installing Switches must be CETL or CUL in Canada or ETL or UL in USA general use switches Refer to the instructions packaged with the light kits...

Страница 3: ...airs Check against parts inventory that all parts have been included 2 Parts Inventory a canopy 1 piece b hanging bracket 1 piece c downrod and hanging ball 1 piece d motor housing 1 piece e yoke cover 1 piece f blade arm 3 pieces g switch housing plate 1 piece h switch housing 1 piece i blade 3 pieces j canopy cover 1 piece k hardware packs IMPORTANT REMINDER You must use the parts provided with ...

Страница 4: ...utlet box be sure the outlet box is securely attached to the building structure and can support the full weight of the fan Ensure outlet box is clearly marked Suitable for Fan Support If not it must be replaced with an approved outlet box Failure to do so can result in serious injury CAUTION Be sure outlet box is grounded properly and that a ground wire GREEN or bare is present Install hanging bra...

Страница 5: ...r to diagram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously removed Tighten yoke set screws and nuts securely Refer to diagram 2 Slide yoke cover canopy cover and canopy over downrod Refer to diagram 3 Note Canopy cover must be turned with smooth side toward...

Страница 6: ...in place and to lift the fan up to you once you are set on the ladder Find a secure attachment point wood ceiling joist highly recommended and secure safety cable It will be necessary to use a heavy duty wood screw washer and lock washer not supplied with the safety cable loop If necessary adjust the loop at the end of the safety cable The loop at the end of the safety cable should just fit over t...

Страница 7: ...e made as follows Connect BLACK and BLUE wire from fan to BLACK wire from ceiling with wire connector provided Connect WHITE wire from fan to WHITE wire from ceiling with wire connector provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from ceiling with wire connector provided Since this fan does not come with a light kit you will need to cap off the BLUE wire with a wir...

Страница 8: ...rious bodily injury DO NOT use power tools to assemble the blades If screws are overtightened blades may crack and break Locate 9 blade attachment screws washers in hardware pack Hold blade arm up to blade and align holes Insert 3 blade attachment screws washers with fingers first and then tighten screws securely with a Phillips screwdriver Repeat for the remaining blades Remove blade arm screws w...

Страница 9: ...to function If the reverse switch is set in the middle position diagram 4 fan will not operate Attach pull chain extension supplied or custom pull chain extension sold separately to the end of the pull chain diagram 1 diagram 2 diagram 3 diagram 4 male plug switch housing plate motor plate motor plate screw switch housing male plug female plug motor housing Remove 1 screw from motor plate on under...

Страница 10: ...ftmade We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY CRAFTMADE will repair or replace at no charge to the original purchaser any fan motor that fails to operate satisfactorily when failure results from normal use RETURN FAN MOTOR ONLY shipping prepaid to Craftmade Industries We will repair or ship purchaser a replacement motor and Craftmade w...

Отзывы: