background image

5. Fan Assembly. (cont.) 

page 5

hanging ball slot

hanging bracket tab

motor housing

safety cable

“J” hook

safety cable loop

wood

ceiling

joist

With the hanging bracket secured to the outlet box and 
able to support the fan, you are now ready to hang your 
fan. Grab the fan firmly with two hands. Slide downrod 
through opening in hanging bracket and let hanging ball 
rest on the hanging bracket. Turn the hanging ball slot 
until it lines up with the hanging bracket tab.

WARNING

: Failure to align slot in hanging ball with tab in 

hanging bracket may result in serious injury or death.

Tip

: Seek the help of another person to hold the 

stepladder in place and to help lift the fan up to you once 
you are set on the ladder. 

Replace vice on safety cable and adjust safety cable length 
by pulling on the cable. Adjust slack in cable to a hands 
length and secure vice by tightening screw and nut 
securely. The loop at the end of the safety cable should 
just fit over the “J” hook. [

Refer to drawing at right.

Find a secure attachment point (wood ceiling joist highly 
recommended) and secure safety cable. It will be 
necessary to use the “J” hook (included) with the safety 
cable loop. 

Test safety cable by pulling on loose end with 

pliers. If the safety cable slips, the screw and nut on the vice 
must be set tighter.

6. Wiring.

WARNING:

 Turn off circuit breakers to current fixture from 

breaker panel and be sure operating light switch is turned 
to the OFF position. 

CAUTION

Be sure outlet box is properly grounded and that 

a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with Local Codes 
or Ordinances and the National Electrical Code. If you are 
unfamiliar with electrical wiring or if the house/building wires 
are different colors than those referred to below, please use a 
qualified electrician.

WARNING

:  If using this fan in a 

DAMP

 location, this fan 

must be connected to a supply circuit that is protected by 
a Ground Fault Circuit Interrupter (GFCI) to reduce the risk 
of personal injury, electrical shock or death.

Note

Excess lead wire length from the fan can be cut to the 

desired length and then stripped.

When downrod is secured in place on the hanging 
bracket, electrical wiring can be made as follows:
Connect 

BLACK

 wire from fan to 

BLACK

 wire from ceiling 

with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from ceiling 

with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from fan to 

BARE

/

GREEN

 wire from ceiling with wire connector 

provided.

* Wrap each wire connector separately with electrical 
tape as an extra safety measure.

Note: Only remote controls approved for DAMP locations 
can be used with this fan.

black

black

white

white

black supply wire

ground

(green

or bare)

white supply wire

*

from ceiling

from fan

ground 
(green or bare)

Содержание DCRT70AG

Страница 1: ...s 5 6 Canopy Assembly pg 6 Blade Assembly pg 7 Switch Housing Assembly pg 7 Automated Learning Process Activating Code pg 8 Testing Your Fan pg 9 Light Kit Assembly Optional pg 10 Troubleshooting pg 11 Warranty pg 11 Parts Replacement pg 11 net weight of fan 19 40 lb 8 8 kg PRINTED IN CHINA READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE For Model DCRT70AG Riata Grande 70 sold separately ...

Страница 2: ...ires consult an electrician for the proper size wire connectors to use WARNING If using this fan in a DAMP location this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI to reduce the risk of personal injury electrical shock or death 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CETL or CUL in ...

Страница 3: ...a canopy 1 piece b hanging bracket 1 piece c 6 in downrod with pin and clip with hanging ball 1 piece d 3 in downrod 1 piece e motor housing 1 piece f yoke cover 1 piece g anti sway adapter in hardware pack 1 piece h switch housing 1 piece i blade arm 5 pieces j wall control 1 piece k plate 1 piece l remote control 1 piece m faceplate 3 pieces n hardware packs page 2 a IMPORTANT REMINDER You must ...

Страница 4: ... using an existing outlet box be sure the outlet box is securely attached to the building structure and can support the full weight of the fan Ensure the outlet box is clearly marked Suitable for Fan Support If not it must be replaced with an approved outlet box Failure to do so can result in serious injury CAUTION Be sure outlet box is grounded and that a ground wire GREEN or bare is present Inst...

Страница 5: ...iagram 2 Slide yoke cover anti sway adapter and canopy over downrod Refer to diagram 3 Note If using the anti sway adapter it must be turned with flat side toward the canopy Thread safety cable and wires through hanging ball and then slide hanging ball over downrod the top of the downrod should be noted as having a set screw hole use this hole when setting the set screw Insert stop pin into top of...

Страница 6: ...iring WARNING Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position CAUTION Be sure outlet box is properly grounded and that a ground wire GREEN or Bare is present Make sure all electrical connections comply with Local Codes or Ordinances and the National Electrical Code If you are unfamiliar with electrical wiring or if th...

Страница 7: ... is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help black OUT to fan green black AC IN f...

Страница 8: ...tachment screws along with washers with fingers first and then tighten screws securely with a Phillips screwdriver Repeat for the remaining blades Remove blade arm screws lock washers from underside of motor If plastic motor locks are installed with blade arm screws discard plastic motor locks save blade arm screws and lock washers to secure blade arms NOTE Additional blade arm screws are located ...

Страница 9: ...cable DIMMER SWITCH Dimming capability is determined by the type of bulbs provided with the light kit ON position D OFF position O FAN OFF Use to turn fan off ON OFF slider switch Wall control only Use to turn wall control on or off Select faceplate for remote control and or wall control and press firmly onto front of remote control wall control IMPORTANT The Automated Learning Process takes 5 min...

Страница 10: ...roubleshooting section to solve any issues before contacting Customer Service Fan must be on LOW before setting the fan in reverse Use button to recirculate air depending on the season A ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort NOTE If the wall remote control interferes with other ...

Страница 11: ...E wire from light kit fitter to WHITE wire from motor housing Connect BLACK wire from light kit fitter to BLUE or BLACK wire from motor housing Be sure molex connections snap together securely Align slotted holes in switch housing with loosened screws in fitter plate Twist switch housing to lock and securely tighten all 3 screws Attach glass shade s to light kit fitter using the hardware provided ...

Страница 12: ...y consequential damages for breach of this or any other warranty expressed or implied whatsoever This limitation as to consequential damages shall not apply in states where prohibited PWLI1505 Problem Fan fails to operate Solutions 1 Check power to wall switch wall control 2 Check to be sure wall control optional use is wired properly 3 Check to be sure fan is wired properly 4 Learning process bet...

Страница 13: ... Colocación de las aspas Pág 7 Instalación de la caja de encendido Pág 7 Proceso de aprendizaje automático Activar el código Pág 8 Verificación del funcionamiento del ventilador Pág 9 Instalación del juego de luz opcional Pág 10 Localización de fallas Pág 11 Garantía Pág 11 Piezas de repuesto Pág 11 IMPRESO EN CHINA LEER ESTAS INSTRUCCIONES Y GUARDARLAS PARA UTILIZACION FUTURA peso neto del ventil...

Страница 14: ...lador al cual corresponda cada uno consultar con un electricista para informarse sobre el tamaño correcto de conectores para cable que se debe usar ADVERTENCIA Si va a utilizar este ventilador en un lugar HUMEDO hay que conectar el ventilador a un circuito de alimentación que esté protegido por un Interruptor de Circuito de Falla de Tierra GFCI por sus siglas en inglés para reducir el riesgo de da...

Страница 15: ...taje 1 unidad c tubo de 15 24cm con perno y clavija y bola que sirve para colgar 1unidad d tubo de 7 62cm 1 unidad e bastidor del motor 1 unidad f cubierta del cuello 1 unidad g adaptador de estabilización en paquete de artículos de ferretería 1 unidad h caja de encendido 1 unidad i brazo para el aspa 5 unidades j control de pared 1 unidad k placa 1 unidad l control remoto 1 unidad m tapa 3 unidad...

Страница 16: ...nales las arandelas de resorte y las arandelas planas de su nueva o existente caja de salida Si hace la instalación en un techo abovedado colocar el soporte de montaje con la abertura dirigida hacia la parte alta del techo Arreglar el alambrado eléctrico los cables en la parte de atrás del soporte y lejos de la abertura del soporte Nota Es muy importante usar los artículos de ferretería correctos ...

Страница 17: ...ubo Referirse al diagrama 3 Nota Si utiliza el adaptador de estabilización se tiene que voltear el adaptador de estabilización para que el lado plano dé a la cubierta decorativa Pasar el cable de seguridad y los cables por la bola que sirve para colgar y luego deslizar la bola que sirve para colgar sobre el tubo la parte de arriba del tubo debe tener el agujero para el tornillo de fijación en ese ...

Страница 18: ...cable provisto Como una medida de seguridad adicional envolver cada conector para cable con cinta aisladora Nota Sólo se pueden utilizar controles remotos que tengan aprobación para lugares HUMEDOS con este ventilador Ya que esté sujetado el soporte de montaje a la caja de salida y capaz de apoyar el ventilador usted está listo para colgar el ventilador Agarrar el ventilador firmemente con las dos...

Страница 19: ...urge al usuario a intentar rectificar la interferencia tomando una o más de las medidas que siguen Orientar la antena de nuevo o localizarla en otro sitio Aumentar la separación entre el equipo y el receptor Conectar el equipo a un tomacorriente en un circuito distinto al cual está conectado el receptor Solicitar ayuda del distribuidor o un técnico de radio televisión cableado del control de pared...

Страница 20: ...s de seguridad para asegurar los brazos para el aspa NOTA Adicionales tornillos para los brazos para el aspa se encuentran en uno de los paquetes de artículos de ferretería Alinear los agujeros de uno de los brazos para las aspas con los agujeros para los tornillos en el motor y fijar el brazo para el aspa con los tornillos arandelas de seguridad para brazos para el aspa Antes de apretar los torni...

Страница 21: ...EL REDUCTOR DE LUZ Se regula la intensidad de la luz dependiendo del tipo de bombillas provistas con el juego de luz Posición APAGADO Off D Posición ENCENDIDO On O Botón de APAGADO Se usa para apagar el ventilador Interruptor corredero ON OFF Control de pared solamente Usar para prender o apagar el control de pared Escoger la s tapa s para el control remoto y o el control de pared y sujetarla fija...

Страница 22: ...rola todas las funciones del ventilador favor de referirse a la sección Localización de fallas para resolver cualquier asunto antes de comunicarse con el Servicio al cliente Hay que poner el ventilador en posición BAJA antes de poner el ventilador en reversa Usar el botón para que circule bien el aire dependiendo de las estaciones del año Un ventilador de techo le permitirá subir el termostato en ...

Страница 23: ...rse al diagrama b Conectar el cable BLANCO del conectador para el juego de luz al cable BLANCO del bastidor del motor Conectar el cable NEGRO del conectador para el juego de luz al cable NEGRO o AZUL del bastidor del motor Asegurarse de que se conecten bien las conexiones tipo molex Alinear los agujeros con ranura en la caja de encendido con los tornillos aflojados en la placa de conexión Girar la...

Страница 24: ...años emergentes no se aplicará en estados donde es prohibido PWLI1505 Problema El ventilador no funciona Soluciones 1 Inspeccionar el interruptor de pared del ventilador control de pared 2 Verificar la instalación eléctrica del control de pared uso opcional 3 Verificar la instalación eléctrica del ventilador 4 Es posible que no tuvo éxito el proceso de aprendizaje entre el ventilador el control re...

Отзывы: