PRODUCT SPECIFICATIONS
Generator Specifications
Rated Maximum Power ...............7,500 Watts (7.5 kW)
Surge Power ................................9,375 Watts (9.3 kW)
Rated AC Voltage ........................120/240 Volts
Rated Maximum AC Load Current
at 240 Volts ..............................31.2 Amperes
at 120 Volts ..............................62.5 Amperes
Rated Frequency .........................60 Hz at 3600 rpm
Phase ..........................................Single Phase
Rated DC Voltage ........................12 Volts
Rated Maximum DC Load Current
at 12 Volts ................................10.0 Amperes
Engine Specifications
Rated Horsepower ........................15 at 3600 rpm
Displacement ................................410 cc
Spark Plug
Type: .................................Champion RC12YC or
Equivalent
Set Gap To:.......................0.030 inch (0.76mm)
Gasoline Capacity.........................7 U.S. gallons
Oil Type:
Summer.............................SAE 30 or 10W-30
Winter................................Synthetic 5W-20 or
5W-30
GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items
that have been subjected to operator abuse or
negligence. To receive full value from the warranty,
the operator must maintain the generator as instructed
in this manual.
Some adjustments will need to be made periodically to
properly maintain the generator.
All adjustments in the Service and Adjustments
section of this manual should be made at least once
each season. Follow the requirements in the
“Maintenance Schedule” chart above.
NOTE
: Once a year you should clean or replace the
spark plug and replace the air filter. A new spark plug
and clean air filter assure proper fuel-air mixture and
help your engine run better and last longer.
GENERATOR MAINTENANCE
Generator maintenance consists of keeping the unit
clean and dry. Operate and store the unit in a clean
dry environment where it will not be exposed to
excessive dust, dirt, moisture or any corrosive vapors.
Cooling air slots in the generator must not become
clogged with snow, leaves, or any other foreign
material.
Check the cleanliness of the generator frequently and
clean when dust, dirt, oil, moisture or other foreign
substances are visible on its exterior surface.
13
MAINTENANCE
‡ Change oil after first 8 hours of operation then after every 50 hours or every season.
* Change oil and oil filter every 25 hours when operating under heavy load or in high temperatures.
** Clean more often under dirty or dusty conditions. Replace cleaner parts if very dirty.
*** Retorque head bolts only after the first 50 hours. Head bolts will not need further retorquing.
MAINTENANCE SCHEDULE
Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when
operating in adverse conditions noted below.
Maintenance Operation
Every 8 Hours
or Daily
25 Hours or
Every Season
50 Hours or
Every Season
100 Hours or
Every Season
Check Oil Level
X
Service Air Pre-Cleaner
X**
Changer Oil And Oil Filter
‡
X*
Clean Spark Arrestor Screen
X
Adjust Valve Clearance
X
Retorque Head Bolts
X***
Service Air Cleaner
X**
Replace Spark Plugs
X