Electrofusion Welder
26/07/2011
www.LaboratoryDrainage.co.uk
Pg 12
DATA LOGGING
If Data Logging is ON at the start of welding, then the parameters of
welding will be recorded. These can subsequently be down loaded into a
portable memory stick for transfer to a computer and subsequent
analysis.
DATA LOG MEMORY
It is possible to enter three pieces of information to identify the weld. The
first is the
Operator’s Name
, the second is the
Location
where the weld is
being done, and the third is an
Information
field for more details.
The display will show all three pieces of information in turn: Enter the
required information and press the
A
key to accept it.
Note:
This information will be saved when the weld has been completed, and
will be prompted the next time a new weld is carried out.
The display will also ask if the pipe/fitting has been abraded and
tightened. Select yes or no using the Start or Stop buttons. This
information will be saved on the data log memory.
DOWNLOADING THE WELD MEMORY
The data log memory is downloaded by using an ‘industry standard’ USB
flash memory device. The data can be encrypted for protection, to stop
unauthorised alteration of the information.
A download program is supplied that un-encrypts the data and allows it
to be viewed, filtered, graphed and printed. This software is supplied on
the USB memory pen. Run the Install file and follow the instructions.