9. Operation:
WARNING
THIS EQUIPMENT GENERATES DANGEROUS VOLTAGES THAT MAY BE FATAL.
PROPER GROUNDING OF ALL HIGH VOLTAGE EQUIPMENT IS ESSENTIAL.
WARNING
THIS EQUIPMENT IS PERMANENTLY CONNECTED THEREFORE IT SHALL OPERATE IN
BUILDINGS WITH A SWITCH OR CIRCUIT BREAKER. THIS EQUIPMENT MUST BE
INSTALLED IN CLOSE PROXIMITY OF THE SWITCH OR CIRCUIT BREAKER WITHIN
EASY REACH OF OPERATOR. THIS SWITCH OR CIRCUIT BREAKER SHALL BE MARKED
AS THE DISCONNECTING DEVICE FOR THE POWER SUPPLY.
CAUTION
BEFORE CONNECTING THE POWER SUPPLY TO THE AC SUPPLY, FOLLOW THIS
STEP-BY-STEP PROCEDURE.
FAILURE TO FOLLOW THESE PROCEDURES MAY VOID THE WARRANTY AND WILL
RESULT IN SAFETY VIOLATION.
Step 1
Turn the power switch at the rear of the power supply to off (0) position.
Step 2
Attach the AC power cord to the power supply and plug the other end to the wall socket.
Step 3
Attach the high voltage output cable to the load. The cable used should be shielded with a wire
braid that functions as the high voltage return. Make sure sufficient clearance and creepage
exists from the live conductor of the cable to high voltage return.
Step 4
Attach the mating plug on the high voltage cable to the HV output receptacle on the supply and
hand tighten. Make absolutely sure that a good high voltage output and high voltage return
connection is made between the supply and the load.
Step 5
The chassis of the high voltage power supply and high voltage cable shield must be solidly
grounded through AC power cord. Check chassis to ground and shield to ground with an
Ohmmeter to ensure reliable grounding.