1. Safety: 

OPERATIONAL SAFETY 

 
THIS POWER SUPPLY GENERATES VOLTAGES THAT ARE DANGEROUS AND MAY BE 
FATAL. OBSERVE EXTREME CAUTION WHEN WORKING WITH THIS EQUIPMENT.  
 
High voltage power supplies must always be grounded. 
 
Do not touch connections unless equipment is off and the capacitances of both the load and 
power supply are discharged. 
 
Do not ground yourself or work under wet or damp conditions. 
 
 

SERVICING SAFETY 

 
Maintenance may require removing the instrument cover with the power on. 
 
Servicing should only be done by qualified personnel aware of the electrical hazards. 
 
“WARNING” notes in the text call attention to hazards in the operation of these units that could 
lead to possible injury or death. 
 
“CAUTION” notes in the text indicate procedures to be followed to avoid possible damage to 
equipment. 
 
Technical and safety assistance can be obtained from: 
     Frank 

Feng 

     7313 

SW 

Tech 

Center 

Dr 

     Portland, 

OR 

97224, 

USA 

  Phone:  503-598 

9595 

  Fax: 

  503-684-8164 

  e-mail:  

[email protected]

 

 

 

 

 

 

 

 

WARNING 

 
IF THE EQUIPMENT IS USED IN ANY MANNER NOT SPECIFIED BY THE CPS, INC. 
(MANUFACTURER), THE PROTECTION PROVIDED IN THE POWER SUPPLY MAY BE 
IMPAIRED CAUSING EQUIPMENT DAMAGE. 

Содержание BP2592 Series

Страница 1: ...ROVED CHECKED DATE DATE 05 14 03 DATE CONTRACT NO DATE PREPARED F Feng SHEET TITLE INSTRUCTION MANUAL BP2592 REV A SPECIFICATION NO BP2592 89 0001 SCALE SIZE A FSCM NO 31640 OF 1 1 1 1 REV DESCRIPTION DATE APPROVAL REVISIONS A RELEASE 05 14 03 FF INSTRUCTION MANUAL for BP2592 Series Bipolar High Voltage Power Supply ...

Страница 2: ... 503 682 8164 WWW CPSHV COM SHEET 2 REV A SPECIFICATION NO BP2592 89 0001 FSCM NO 31640 SIZE A Table of Contents 1 Safety 3 2 Definitions of Symbols 4 3 Introduction 5 4 Features 5 5 Electrical Specifications 5 6 Block Diagram 6 7 Environmental conditions 6 8 Mechanical Specifications including connectors 6 9 Operation 8 10 Warranty 10 ...

Страница 3: ...lf or work under wet or damp conditions SERVICING SAFETY Maintenance may require removing the instrument cover with the power on Servicing should only be done by qualified personnel aware of the electrical hazards WARNING notes in the text call attention to hazards in the operation of these units that could lead to possible injury or death CAUTION notes in the text indicate procedures to be follow...

Страница 4: ...TER DRIVE PORTLAND OR 97223 USA PH 503 598 9595 FAX 503 682 8164 WWW CPSHV COM SHEET 4 REV A SPECIFICATION NO BP2592 89 0001 FSCM NO 31640 SIZE A 2 Definitions of Symbols Direct Current Protective Conductor Terminal Caution refer to accompanying documents Caution risk of electric shock ...

Страница 5: ...larity reversal on the fly Three HV output connectors Output voltage softening resistors Voltage programming via panel mount potentiometer Voltage metering front panel digital display 5 Electrical Specifications Output Polarity Positive or negative reversible by user Output Voltage 30kV to 30kVDC programmable Output Current 300µA rated Output Ripple 0 1 peak to peak of output voltage Load Regulati...

Страница 6: ...must operate under following conditions the equipment is intended for indoor use only operating temperature 0 to 500 C altitude up to 1000 m maximum relative humidity 80 at 310 C and 50 at 400 C installation Category Intended for use in installation category overvoltage category II IEC 1010 1 standard Pollution Degree Category 2 IEC 1010 1 standard 8 Mechanical Specifications Output mating connect...

Страница 7: ...ITLE INSTRUCTION MANUAL BP2592 7313 SW TECH CENTER DRIVE PORTLAND OR 97223 USA PH 503 598 9595 FAX 503 682 8164 WWW CPSHV COM SHEET 7 REV A SPECIFICATION NO BP2592 89 0001 FSCM NO 31640 SIZE A Fig 2 Physical layout 18 3 19 0 2 25 5 25 13 0 ...

Страница 8: ...EDURE FAILURE TO FOLLOW THESE PROCEDURES MAY VOID THE WARRANTY AND WILL RESULT IN SAFETY VIOLATION Step 1 Turn the power switch at the rear of the power supply to off 0 position Step 2 Attach the AC power cord to the power supply and plug the other end to the wall socket Step 3 Attach the high voltage output cable to the load The cable used should be shielded with a wire braid that functions as th...

Страница 9: ...utput voltage increases as indicated by the output voltage digital display panel Note the potentiometer has 300 degree rotation to change output voltage from 0V to an absolute value of 30kV full scale Step 10 To change polarity of the output voltage without changing the absolute value use polarity select switch Output voltage will reduce gradually then ramp to the voltage of the opposite polarity ...

Страница 10: ...ially lethal voltages are generated inside the module 10 Warranty COMPUTER POWER SUPPLY Inc CPS warrants equipment of its manufacture against defective materials or workmanship for a period of one year from the date of shipment CPS will repair or replace any defective product which was not damaged by negligence misuse improper installation accident unauthorized repair or alteration by the Buyer Th...

Отзывы: