71
Chapter 7 Maintenance and De-installation
7.1 Fault shut down and troubleshooting
7.1.1 LED fault and troubleshooting
Please refer to the definition of LED lights in Table 5-1 and troubleshoot
according to Table 7-1:
Table 7-1 Trouble shooting of LED lights
LED fault status
Solutions
Neither
the “Power” LED nor the
LCD screen lights up.
1. Turn off the external AC
breaker
2. Switch
the DC switch to “OFF”
position
3. Check the PV input voltage and
polarity
The
“GRID” LED is blinking.
1. Turn off the external AC
breaker
2.
Switch the DC switch to “OFF”
position
3. Check whether the grid voltage
is normal and whether the cable
connection of AC side is correct
and secure
The “RUN” LED lights off or “FAULT”
LED lights up.
Refer
to
Table
7-2
for
troubleshooting
7.1.2 LCD fault and troubleshooting
The inverter will be shut down automatically if the PV power generation
system fails, such as output short circuit, grid overvoltage / undervoltage, grid