M P A H U B M O U N T
between Fault and another operational state. This guarantees that a
hard fault will ultimately latch the unit into Fault. If a recycle
decision is made, the unit remains in the Fault state for, an
additional 0.5 second before cycling back to the original state.
If the unit enters Fault from HTD, the HTD countdown will
continue.
While the unit is in the Fault state, the Fault LED flashes. Once the
unit leaves the Fault state, the Fault LED is OFF.
If the unit is latched into the Fault state, the Fault LED flashes. To
exit the latched Fault state, the user must clear the fault cause, then
toggle the RESET switch. The amplifier returns to Standby.
5.6.7.2 Fault
log
A fault log is available to the user via either the remote panel or the
CPI supplied remote software. Refer to either chapter 3 (Figure 3-5)
or to Appendix B for more information on how to access the log.
Doc. 01031254 Rev. 1
5-9
Содержание T04CO
Страница 32: ...I N S T A L L A T I O N 2 10 Installation and Operation Manual This page is intentionally left blank ...
Страница 41: ...M P A H U B M O U N T Figure 3 5 Remote Control Unit Menu Tree Doc 01031254 Rev 1 3 9 ...
Страница 68: ...O P E R A T I O N 5 10 Installation and Operation Manual This page intentionally left blank ...
Страница 74: ...D R A W I N G S 7 2 Installation and Operation Manual This page is intentionally left blank ...
Страница 92: ...MPA Hub Mount I O Manual C 2 Replaceable parts Doc 01031254 Rev 1 This page is intentionally left blank ...
Страница 94: ...MPA Hub Mount I O Manual D 2 Optional Linearizer Doc 01031254 Rev 1 This page is intentionally left blank ...
Страница 96: ...MPA Hub Mount I O Manual E 2 Optional L band BUC Doc 01031254 Rev 1 This page is intentionally left blank ...
Страница 112: ...MPA Hub Mount I O Manual Appendix G 14 Doc 01031254 Rev 1 This page is intentionally left blank ...