I N I T I A L P O W E R - O N A N D C H E C K O U T
Press the FUNCTIONS key to access the FUNCTIONS menu.
Press the FUNCTION key
repeatedly to scroll through the
choices listed below the FUNCTION box. In the REMOTE mode
use the
keys to raise or lower the parameter value. Press
ENTER
to accept the new value and then use the FUNCTION key
to return to the Main Menu (scroll to the end of the list) or press the
Meters key one time. In the LOCAL mode you can scroll through
the FUNCTION list, but you cannot change the parameter values.
3.4
Operation with PC Computer and Setup
& Remote Control Software
This software allows the user to set up and remotely control the
MPA via a PC computer running in DOS mode with the CPI
supplied remote software. The functions, controls and monitors are
the same as those accessed by the remote control panel.
Refer to Appendix B for a complete description of operation with
this software program.
3.5 First Time Pre-Power Procedure
Before applying prime AC power to the MPA Hub Mount, verify
that the following conditions are met:
•
AC prime power is 100 - 240 VAC +/- 10%, 47-63 Hz, as
indicated by the label located on exhaust end of unit, and single
phase.
•
The AC power cord is connected to J1, but the AC power is not
turned on.
•
A ground strap is connected from the station's ground bus to
the 6-32 ground screw-mounting hole located on the amplifier
front panel.
•
The RF Input and RF Output are connected to a matched source
and test load. RF input power is off.
•
All RF connections are terminated and tight.
3-10
Installation and Operation Manual
Содержание T04CO
Страница 32: ...I N S T A L L A T I O N 2 10 Installation and Operation Manual This page is intentionally left blank ...
Страница 41: ...M P A H U B M O U N T Figure 3 5 Remote Control Unit Menu Tree Doc 01031254 Rev 1 3 9 ...
Страница 68: ...O P E R A T I O N 5 10 Installation and Operation Manual This page intentionally left blank ...
Страница 74: ...D R A W I N G S 7 2 Installation and Operation Manual This page is intentionally left blank ...
Страница 92: ...MPA Hub Mount I O Manual C 2 Replaceable parts Doc 01031254 Rev 1 This page is intentionally left blank ...
Страница 94: ...MPA Hub Mount I O Manual D 2 Optional Linearizer Doc 01031254 Rev 1 This page is intentionally left blank ...
Страница 96: ...MPA Hub Mount I O Manual E 2 Optional L band BUC Doc 01031254 Rev 1 This page is intentionally left blank ...
Страница 112: ...MPA Hub Mount I O Manual Appendix G 14 Doc 01031254 Rev 1 This page is intentionally left blank ...