5
GENERAL INSTALLATION INSTRUCTIONS
Ensure gas supply and gas type, as shown on unit nameplate, match.
Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the National
Gas Installation Code, CSA B149.1, or the Propane Installation Code, CSA B149.2 as applicable and
in accordance with local codes.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand.
Level the unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs
mounted, lift if necessary to move unit.
Pipe threading compound must be resistant to the action of liquefied petroleum gases.
Caution: DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and
water solution before operating unit.
THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON COMBUSTIBLE SURFACES ONLY.
Combustible clearances:
6" sides (152 mm)
6" rear (152 mm) 4" floor (102 mm)
Noncombustible clearances:
0" sides (0 mm)
0" rear (0 mm)
4" floor (102 mm)
Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the
unit by the flue.
Adequate clearance for air openings into the combustion chamber is required. Do not place objects
between the bottom of the unit and the counter top.
There must be adequate clearance for removal of the front panel. All major parts except the burners
are removable through the front if the gas line is disconnected.
SPECIFICATION AND DIMENSIONS
MODEL
WIDTH
IN. (MM)
DEPTH
IN. (MM)
HEIGHT
IN. (MM)
# OF
BURNERS
BTU/PER
NAT/LP
TOTAL
BTU/ Hr
W.C.
IN.
CK HPSU212
12(305)
26.8(680)
18.9(480)
2
30,000
60,000
6/10
CK HPSU424
24(610)
26.8(680)
18.9(480)
4
30,000
120,000
6/10
CK HPSU636
36(915)
26.8(680)
18.9(480)
6
30,000
180,000
6/10