LOCATION OF DATA PLATE

The data plate is located on the side panel.

IMMEDIATELY INSPECT FOR SHIPPING DAMAGE

Equipment should be examined for damage before and during unloading. The freight carrier has

assumed responsibility for its safe transit and delivery. If equipment is received damaged, either

apparent or concealed, a claim must be made with the delivering carrier.

A) Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then be

signed by the carrier representative (Driver). If this is not done, the carrier may refuse the claim. The

carrier can supply the necessary forms.

B) If concealed damage or loss is not apparent until after equipment is uncrated, a request for

inspection must be made to the carrier within 15 days. The carrier should arrange an inspection. Be

certain to hold all contents and packaging material.

Installation should be performed by a qualified installer who thoroughly read, understands and

follows these instruction.

If you have questions concerning the installation, operation, maintenance or service of this product,

visit Cooking Performance Group’s website at www.CookingPerformanceGroup.com.

SAFETY PRECAUTIONS

DANGER This symbol warns of imminent hazard which will result in serious injury or

death.

WARNING: This symbol refers to a potential hazard or unsafe practice, which could result

in serious injury or death.

CAUTION: This symbol refers to a potential hazard or unsafe practice, which could result

in minor or moderate injury or product or property damage.

NOTICE: This symbol refers to information that needs special attention or must be fully

understood even though not dangerous.

NOTICE: This product is intended for commercial use only. Not for household use.

NOTICE: Local codes regarding installation vary greatly from one area to another. The National

Fire Protection Association, Inc., states in its NFPA96 latest edition that local codes are

“Authority Having Jurisdiction” when it comes to requirement for installation of

equipment. Therefore, installation should comply with all local codes.

Содержание CK HPSU212

Страница 1: ...1 USER MANUAL Gas Step Up Hot Plate MODELS CK HPSU212 CK HPSU424 CK HPSU636 06 2017...

Страница 2: ...ion can be obtained from your local gas supplier CAUTION These models are designed built and sold for commercial use only If these models are positioned so the general public can use the equipment mak...

Страница 3: ...ars of reliable operation from this equipment To ensure best results it is important that you read and follow the instructions in this manual carefully TABLE OF CONTENTS ITEM PAGE ITEM PAGE Safety pre...

Страница 4: ...y read understands and follows these instruction If you have questions concerning the installation operation maintenance or service of this product visit Cooking Performance Group s website at www Coo...

Страница 5: ...TS ARE SUITABLE FOR INSTALLATION ON NON COMBUSTIBLE SURFACES ONLY Combustible clearances 6 sides 152 mm 6 rear 152 mm 4 oor 102 mm Noncombustible clearances 0 sides 0 mm 0 rear 0 mm 4 oor 102 mm Do no...

Страница 6: ...the front panel 1 Remove the knobs and front panel 2 Uns 2 Remove the burner from the top of the gas pipe 1 Remove the trivets from the top of the appliance Note Unit Number on side of ori ce ttings P...

Страница 7: ...cient air supply results in a yellow streaming ame Primary air supply is controlled by an air shutter on the front of the burner 2 Loosen the screws on the front of the burner and adjust the air shut...

Страница 8: ...grabbing the handle and pulling it out of the opening in the front panel To replace the pan reverse this procedure 3 Burner air shutter openings must be kept clean Main burner ports must be kept clean...

Страница 9: ...9 EXPLOSION VIEW DRAWING MODEL CK HPSU424...

Страница 10: ...1068643 2 4 6 CK HPSU212 LPG CK HPSU424 LPG CK HPSU636 LPG 01 20 1068652 2 4 6 6 Burner CK HPSU212 CK HPSU424 CK HPSU636 06 05 1472521 2 4 6 7 Grate CK HPSU212 CK HPSU424 CK HPSU636 01 03 1015096 2 4...

Страница 11: ...PSU424 CK HPSU636 06 05 1473193 1 2 3 14 Valve connection CK HPSU212 CK HPSU424 CK HPSU636 66 04 1820085 2 4 6 15 Valve CK HPSU212 CK HPSU424 CK HPSU636 01 20 1068502 2 4 6 16 Pilot valve CK HPSU212 C...

Страница 12: ...or equipment failure occurs because of accident carelessness lack of proper set up supervision when required or if the equipment is installed or operated in any manner contrary to the installation and...

Отзывы: