LOCATION OF DATA PLATE 

The data plate is located on the side panel. 

IMMEDIATELY INSPECT FOR SHIPPING DAMAGE 

All equipment should be examined for damage before and during unloading. The freight carrier 

has assumed responsibility for its safe transit and delivery. If equipment is received damaged, 

either apparent or concealed, a claim must be made with the delivering carrier. 

 

A) Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then 

be signed by the carrier representative (Driver). If this is not done, the carrier may refuse the claim. 

The carrier can supply the necessary forms. 

 

B) If concealed damage is not apparent until after equipment is uncrated, a request for inspection 

must be made to the carrier within 15 days. The carrier should arrange an inspection. Be certain to 

hold all contents and packaging material. 

 

Installation and service  should be performed by a qualified installer who thoroughly reads, 

understands and follows these instructions. 

 

If you have questions concerning the installation, operation, maintenance or service of this 

product, visit Cooking Performance Group’s website at 

www.CookingPerformanceGroup.com

 

SAFETY PRECAUTIONS 

 

DANGER

This  symbol warns of imminent hazard which will result in serious injury or 

death. 

 

WARNING: 

This symbol refers to a potential hazard or unsafe practice, which could result 

in serious injury or death. 

 

CAUTION: 

This symbol refers to a potential hazard or unsafe practice, which could result 

in minor or moderate injury or product or property damage. 

 

NOTICE: 

This symbol refers to information that needs special attention or must be fully 

understood even though not dangerous. 

 

NOTICE: 

This product is intended for commercial use only. Not for household use. 

 

 

  NOTICE: 

Local codes regarding installation vary greatly from one area to another. The 

National Fire Protection Association, Inc., states in its NFPA96 latest edition that local 

codes are “Authority Having Jurisdiction” when it comes to requirement for installation 

 

 

 

of equipment. Therefore, installation should comply with all local codes. 

 

 

 

 

 

 

 

Содержание CBL15

Страница 1: ...as Safety information can be obtained from your local gas supplier CAUTION These models are designed built and sold for commercial use only If these models are positioned so the general public can use...

Страница 2: ...l experience years of reliable operation from this equipment To ensure best results it is important that you read and follow the instructions in this manual carefully TABLE OF CONTENTS ITEM PAGE ITEM...

Страница 3: ...ughly reads understands and follows these instructions If you have questions concerning the installation operation maintenance or service of this product visit Cooking Performance Group s website at w...

Страница 4: ...N NON COMBUSTIBLE SURFACES ONLY Combustible clearances 6 sides 152 mm 6 rear 152 mm 4 oor 102 mm Noncombustible clearances 0 sides 0 mm 0 rear 0 mm 4 oor 102 mm Do not obstruct the ow of combustion an...

Страница 5: ...panel 1 Remove the knobs and front panel 2 Uns 2 Unscrew bolts and pilot valve then remove the manifold 1 Remove the knobs and front panel Note Unit Number on side of orifice fittings Plastic Insert...

Страница 6: ...n the screws on the front of the burner and adjust the air shutter to just eliminate the yellow tips of the burner flame Lock the air shutter in place by tightening the screws CAUTION Never attempt to...

Страница 7: ...supports Radiants should be centered over the straight section of the burners COOKING GRATES Place the top cooking grates with the grid bars sloping toward the front as shown in Sketch 2 NOTE When co...

Страница 8: ...t are not to be adjusted by the installer unless the installer is an authorized service agent TOUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE Heat does not come on when valve is on Pilot burner not lit Ga...

Страница 9: ...9 EXPLOSION VIEW DRAWING MODEL CBL24 CBR24...

Страница 10: ...R48 8 2 Cast Radiant CBR15 01 03 1015048 2 CBR24 4 CBR36 6 CBR48 8 3 Regulator 6 NAT or 10 LP 3 4 PT CBL15 CBR15 01 22 1069501 1 CBL24 CBR24 CBL36 CBR36 CBL48 CBR48 4 Stainless Steel Burner Assy U Sha...

Страница 11: ...t Pipe CBL15 CBR15 06 05 1472152 1 CBL24 CBR24 2 CBL36 CBR36 3 CBL48 CBR48 4 8 Pilot valve CBL15 CBR15 01 20 1068509 1 CBL24 CBR24 2 CBL36 CBR36 3 CBL48 CBR48 4 9 Valve For Manual CBL15 CBR15 01 20 10...

Страница 12: ...e 49 LPG CBL15 CBR15 01 20 1068649 1 CBL24 CBR24 2 CBL36 CBR36 3 CBL48 CBR48 4 12 Cast Iron Lava Rack CBL15 01 03 1015106 2 CBL24 4 CBL36 6 CBL48 8 13 Lava Rock CBL15 06 05 1472464 1 CBL24 2 CBL36 3 C...

Страница 13: ......

Страница 14: ......

Страница 15: ...V1 Rev1 12 14...

Страница 16: ...e occurs because of accident carelessness lack of proper set up supervision when required or if the equipment is installed or operated in any manner contrary to the installation and operating instruct...

Отзывы: