USER MANUAL

 Made in China
 Item # 351CLCPG15
 Model # CBL15
 LAVA BRIQUETTE CHARBROILER 15"
 Total BTU: 40,000
 Gas Type: Natural gas
 Manifold Pressure: 6" WC 
 Orifice Size: # 36

CBL15-NG(CPG)

04.03.1317582

Arial  6.5pt

Arial  6.5pt

Arial  6.5pt

Arial Bold  9pt

Arial Bold  6.5pt

1

2

3

4

编号

内容

名称

公司LOGO

认证LOGO

认证LOGO

大小:37.5*29毫米

大小:10*13.7毫米

大小:16.5*16毫米

文件规格明细:

Black

 

Black

 

COLOR:

铭牌标贴(自制)

修改序列号格式

修改铭牌材质

修改铭牌尺寸

C

1

2

3

4

变量, 11:年份  01:月份  000001 序列号

序 列 号

 CLEARANCE REQUIREMENTS:
 Combustible Sides: 6” 
 Combustible Back:  6” 
 Serial # 1101000001

Conforms to ANSI STD Z83.11-2016 and certified to CSA 1.8 STD-2016
Conforms to NSF / ANSI STD. 4

Lancaster, Pennsylvania                                        

135

135

技术要求:须符合ROHS要求

 

  WARNING 

• Equipment must be installed by a certified technician. Improper installation, adjustment,

  alteration, service, or maintenance of this equipment may cause property damage or

  personal injury and voids warranty. 

• Carefully read and follow the installation and owner's manual prior to equipment installation or use.

• Properly attach the legs provided before appliance is permanently installed and before use.

• Use only on non-combustible countertops and away from any combustible material. 

• Equipment must be installed under proper ventilation as required per local code.

• Conversion to other gas types must be performed by a certified technician only.

This appliance is equipped with a gas pressure regulator. The regulator is factory set at 6” WC for nat, or 10” WC for 

propane. For your safety, call an authorized technician for any gas conversion changes. Do not attempt to make conversion 

changes yourself.
Any changes made by a non-authorized technician voids warranty. This appliance has been regulated for:

                    Natural gas             6” WC factory setting
                         Propane            10” WC factory setting

Note: An authorized technician may convert this unit from one gas type to the other.
Prior to conversion, the unit must be adjusted to the correct gas pressure.

Lighting Instructions

1. Turn all knobs until they are straight up-and-down in the vertical position.

2. Turn on the main valve, and wait 10 seconds to clear the gas for first use.

3. Hold an ignition source (match) at the pilot. When the flame is established, remove the ignition source.

4. Turn the burner knobs to "HIGH". If the burner does not ignite, promptly increase gas flow by continuing to open the pilot valve.

  Do this carefully. If the pilot flame appears larger than necessary, turn it down, and reset the burner ignition.

  The pilot flame should be just large enough to guarantee reliable burner ignition when the knobs are in the vertical position.

Note: To turn off the pilot burner, the gas supply must first be cut off.

铝板

A6061 T=0.8 

阳极发黑

Made in China
Item # 351FCPG15N
Model # CF15-NG
COUNTERTOP FRYER 15LB.
Total BTU: 26,500
Gas Type: Natural Gas
Manifold Pressure: 4” WC
Orifice Size: # 54
CLEARANCE REQUIREMENTS:
Combustible Sides: 6”
Combustible Back: 6”
Serial # 1010101010101
Conforms to ANSI STD Z83.11-2016 and certified to CSA 1.8 STD-2016
Conforms to NSF / ANSI STD. 4

Cooking Performance Group 

     

 .  

     

       https://www.cookingperformancegroup.com/

NOTE: The serial plate is located 

on the inside of the unit .

Installation and service should be performed by a qualified installer who thoroughly reads, understands 

and follows these instructions . 

If you have questions concerning the installation, operation, maintenance or service of this product, visit 

Cooking Performance Group’s website at www .CookingPerformanceGroup .com .

Safety Precautions

CAUTION: 

Potential hazard or unsafe practice could result in minor or moderate injury or product or 

property damage .  

NOTICE:

 Local codes regarding installation vary greatly from one area to another . The National Fire 

Protection Association, Inc ., states in its NFPA96 latest edition that local codes are “Authority Having 

Jurisdiction” when it comes to requirement for installation of equipment . Therefore, installation should 

comply with all local codes . 

WARNING:

 

•  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance .

•  Improper installation, adjustment, alteration, service or maintenance could lead to property damage, 

injury or death . Read the installation, operating and maintenance instructions thoroughly before 

installing or servicing CPG equipment . This manual must be retained for future reference .

•  Instructions must be posted in a prominent location . All safety precautions must be taken in the event 

the user smells gas . Safety information can be obtained from your local gas supplier .

•  A factory authorized agent should handle all maintenance and repair . Prior to conducting any 

maintenance or repair work contact an authorized service agency . 

GAS PRESSURE: 

The appliance and its individual shutoff valve (to be supplied by user) must be 

disconnected from the gas supply piping system during any pressure testing of that system at test 

pressures in excess of 1/2 PSI (3 .45 kPa) . The appliance must be isolated from the gas supply piping system 

by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system 

at test pressures equal to or less than 

1/2 PSI (3 .45 kPa) .

Serial Plate

User Manual

Cooking Performance Group 

     

 .  

     

       https://www.cookingperformancegroup.com/

Содержание 351FCPG15L

Страница 1: ...REVISED 02 2022 User Manual Fryers Cooking Performance Group https www cookingperformancegroup com 351FCPG15L 351FCPG15N 351FCPG30L 351FCPG30N...

Страница 2: ...ns 7 Parts Diagram List 8 9 Troubleshooting 10 Congratulations on your purchase of Cooking Performance Group commercial cooking equipment Cooking Performance Group takes pride in the design and qualit...

Страница 3: ...hese instructions If you have questions concerning the installation operation maintenance or service of this product visit Cooking Performance Group s website at www CookingPerformanceGroup com Safety...

Страница 4: ...on must be made to the carrier within 15 days The carrier should arrange an inspection Be certain to hold all contents and packaging material Installation and service should be performed by an authori...

Страница 5: ...your CPG Fryer could be permanently damaged Operating Instructions CPG Fryers are furnished with a Gas Control Safety Valve system It is recommended that the following steps be followed to ensure safe...

Страница 6: ...ou clean and remove the protective oil from the bright parts and interior of tank with a solution of washing soda or other grease dissolving product DAILY CLEANING Frequency of cleaning should depend...

Страница 7: ...clean damp cloth NOTE Thin films of oil subjected to frying temperatures could quickly form into a gummy tough to remove formation In order to avoid such gummy formations clean the surfaces on a regul...

Страница 8: ...ity of fresh frying compound daily without overloading tank If 15 of frying compound is not used daily remove necessary frying compound to permit adding 15 of fresh compound daily 6 Do not overload fr...

Страница 9: ...od Excessive Smoking of Frying Compound Excessive Darkening of Frying Compound Frying Compound Won t Hold Heat Food Crust Color Not Brown Rapid Breakdown of Frying Compound Contamination of Fryer Comp...

Страница 10: ...lame Device System CF15 NG CF15 LPG 01 21 1069001 1 CF30 NG CF30 LPG 01 21 1069003 10 Thermopile CF15 NG CF15 LPG 03 11 1250027 1 CF30 NG CF30 LPG 11 Gas Thermostat CF15 NG CF15 LPG 03 05 1220047 1 CF...

Страница 11: ...www CookingPerformanceGroup com 11 USER MANUAL Parts Diagram User Manual Cooking Performance Group https www cookingperformancegroup com...

Отзывы: