2. Constraints
Concrete Moisture Meter CP-D4 does not detect concrete humidity through electricity conducting materials
like metal coverings/linings, PE-rubber or any wet surfaces. Moisture Meter CP-D4 should not be used to
measure concrete humidity on surfaces which are topped with a thick layer of floor covering material like
wood. Meter measurement outcomes show the actual humidity at a time of measurement.
scale
ndicator
SET button
sensor plate
To turn on the meter press ON/HOLD button.
Use the SET button to select the measuring scale:
1 - Concrete (0-6% H2O)
2 - Cement Screed (0-6% H2O)
3 - Cement Screed (0-4% CM)
4 - Anhydrite Screed (0-3.5% H2O)
5 - Anhydrite Screed (0-1.9% CM)
6 - Caisson 0.3-15.3 Scale (0.3-15.3m)
7 - Relative Scale (0-100%
Name of chosen scale will appear in the scale indicator field.To see detailed description of each scale go to
Available scales section.
•
To set the mode of measurement press ON/HOLD button. There are 2 available modes: Normal, Max
Hold.
ON/HOLD
button
baterry
status
spring
electrode