Troubleshooting
5-10
Coway co., Ltd
Function
Detailed operation
2.
Water level
and valve
control
6) Detailed operating specifications
Low
water
level
sensor
Full
water
level
sensor
Overflow
sensor
Operation
Indicator
Feed
valve
NOS
valve
Non-
detection
0
⇓
Non-
detection
0
⇓
Non-
detection
0
⇓
Water filtration
operation
ON
OFF
Detection
1
⇑
Non-
detection
0
⇓
Non-
detection
0
⇓
Water filtration
operation
ON
OFF
Detection
1
⇑
Detection
1
⇑
Non-
detection
0
⇓
Water full
operation
The feed
valve is
turned off
3 seconds
after the
full water
level is
detected.
OFF
Detection
1
⇑
Non-
detection
0
⇓
Non-
detection
0
⇓
Re-filtration
operation
When the low
water level is
detected and the
full water level is
not detected for
15 minutes
ON
OFF
Non-
detection
0
⇓
Non-
detection
0
⇓
Non-
detection
0
⇓
Re-filtration
operation
Once the low
water level is
detected, the feed
valve is turned on.
ON
OFF
Содержание P-220L
Страница 1: ...P 220R L ...
Страница 2: ......
Страница 10: ...1 6 Coway co Ltd MEMO ...
Страница 14: ...2 4 Coway co Ltd MEMO ...
Страница 20: ...3 6 Coway co Ltd MEMO ...
Страница 45: ...Coway co Ltd 5 13 MEMO ...
Страница 48: ...6 3 Coway co Ltd MEMO ...
Страница 51: ...Parts location diagrams Coway co Ltd 7 3 4 Harness FEED NOS Valve connection 5 Haress LPS Extension ...
Страница 52: ...Parts location diagrams 7 4 Coway co Ltd 7 3 Water piping diagram 7 3 1 P 220R 7 3 2 P 220L ...
Страница 56: ...7 8 Coway co Ltd MEMO ...