Troubleshooting
Coway co., Ltd
5-5
5-2 Control Specifications
5-2-1 Basic Specifications
Scope
These specifications cover the electronic controller (hereafter "PBA") applied to the Woongjin Coway
water filtration device (SAVE [P-220R/L]).
Operating conditions
Item
Description
Power
Refer to the rating plate.
Surrounding
temperature
Custody
environment
-20 °C ~ ±85 °C
Operating
environment
-10 °C ~ ±70 °C
Surrounding Humidity
30 ~ 90 % RH (only in conditions without condensation)
Rated time
Continuous operation
Construction of the power block and major parts
Item
Description
SMPS power
block
Input voltage
Refer to the rating plate.
Output
voltage
DC 5 V, DC 24 V
PBA input
part
External input
- Refer to the rating plate.
- SMPS voltage (DC 5 V, DC 24 V)
- Water level sensor: Detects the low and full levels.
- Overflow sensor: Detects a water overflow
TACT Switch
Input
Extraction button switch: Electronic type extraction valve driving
switch
PBA output
part
Indicator
Indicates whether the extraction is available
Valve control
- FEED valve: Controls the feed water inlet
- NOS valve: Prevents water overflowing
- Extraction valve: Controls the extraction
Содержание P-220L
Страница 1: ...P 220R L ...
Страница 2: ......
Страница 10: ...1 6 Coway co Ltd MEMO ...
Страница 14: ...2 4 Coway co Ltd MEMO ...
Страница 20: ...3 6 Coway co Ltd MEMO ...
Страница 45: ...Coway co Ltd 5 13 MEMO ...
Страница 48: ...6 3 Coway co Ltd MEMO ...
Страница 51: ...Parts location diagrams Coway co Ltd 7 3 4 Harness FEED NOS Valve connection 5 Haress LPS Extension ...
Страница 52: ...Parts location diagrams 7 4 Coway co Ltd 7 3 Water piping diagram 7 3 1 P 220R 7 3 2 P 220L ...
Страница 56: ...7 8 Coway co Ltd MEMO ...