10. Personal Safety:

a.  Wear safety glasses at all times when 

working with pumps.

b.  Keep work area clean, uncluttered and 

properly lighted – replace all unused tools 

and equipment.

c.  Keep visitors at a safe distance from 

work area.

d.  Make workshop child-proof – with 

padlocks, master switches, and by 

removing starter keys.

11. When wiring an electrically driven pump, 

follow all electrical and safety codes 

that apply.

12. 

 Risk of electric shock. Can 

shock, burn or kill. This equipment is only for 

use on 115 volt (single phase) and is equipped 

with an approved 3-conductor cord and 

3-prong, grounding-type plug.

•  To reduce risk of electric shock, pull plug 

before servicing. This pump has not been 

investigated for use in swimming pool areas. 

Pump is supplied with a grounding conductor 

and grounding-type attachment plug. Be sure 

it is connected only to a properly grounded 

grounding-type receptacle.

•  Where a 2-prong wall receptacle is 

encountered, it must be replaced with properly 

grounded 3-prong receptacle installed in 

accordance with codes and ordinances 

that apply.

13. All wiring should be performed by a 

qualified electrician.

14. Make certain power source conforms to 

requirements of your equipment.

15. Protect electrical cord from sharp objects, hot 

surfaces, oil, and chemicals. Avoid kinking 

cord. Replace or repair damaged or worn 

cords immediately.

16. 

 Risk of burns. Do not touch 

an operating motor. Motors can operate at 

high temperatures.

17. Do not handle pump or pump motor with 

wet hands or when standing on wet or damp 

surface, or in water.

 

 Risk of electric shock. Can 

shock, burn or kill. If your basement has 

water or moisture on floor, do not walk on 

wet area until all power has been turned off. 

If shut-off box is in basement, call electric 

company or hydro authority to shut-off service 

to house, or call your local fire department 

for instructions. Remove pump and repair or 

re place. Failure to follow this warning can 

result in fatal electrical shock.

18. Do not lift pump by power cord.

Installation

Tools Required:
Pipe wrench, Strap Wrench, or Slip-Joint Pliers,
Hacksaw,
Screw Driver,
File or Sandpaper
Materials Required:
1-1/2” ABS or PVC Pipe with Cement to match
Threaded Adapter (Pipe to Pump)
Check Valve – Purchase a FP0026-10 (goes 

in the discharge line) or FP0026-6D (goes in 

the pump discharge). If your check valve does 

not have an 1/8” anti-airlock hole, drill one in 

the discharge pipe just above where it screws 

into the pump discharge. Be sure to install the 

check valve so that the flow will be away from 

the pump 
1.  Install pump in sump pit with minimum sump 

size: 10” (254mm) diameter by 10” (254mm) 

depth. Construct sump pit of tile, concrete, 

steel or plastic, as shown in Figure 1. Check 

local codes for approved materials and for 

proper installation.

2.  Pump should not be installed on clay, earth or 

sand surfaces. Clean sump pit of small stones 

and gravel which could clog pump. Keep 

pump inlet screen clear.

 

NOTICE Do not use ordinary pipe joint 

compound on plastic pipe. Pipe joint 

compound can attack plastics.

3.  Install discharge plumbing. Use rigid plastic 

pipe and wrap threads with PTFE pipe thread 

sealant tape. Screw pipe into pump hand tight 

plus 1-1/2 turns.

Safety • Installation 

4

Hard Surface –

No Sand, Clay, 

Gravel

Sump Pit

10" Minimum

10" Min

4824 1011

Figure 1

Содержание CLVS50C

Страница 1: ...800 526 3757 Web Site tractorsupply com 2011 CL877 12 07 11 Installation Operation Parts For further operating installation or maintenance assistance Call 1 800 535 4950 English Pages 2 9 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 535 4950 Español Páginas 10 17 6209 0410 ...

Страница 2: ...untains salt water or brine will void warranty Do not use where water recirculates Not designed for use as a swimming pool drainer General Safety Information Electrically powered sump pumps normally give many years of trouble free service when correctly installed maintained and used However unusual circumstances interruption of power to the pump dirt debris in the sump flooding that exceeds the pu...

Страница 3: ...ducts used in commercial rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receip...

Страница 4: ...ter Risk of electric shock Can shock burn or kill If your basement has water or moisture on floor do not walk on wet area until all power has been turned off If shut off box is in basement call electric company or hydro authority to shut off service to house or call your local fire department for instructions Remove pump and repair or re place Failure to follow this warning can result in fatal ele...

Страница 5: ...adiator hose can be connected into discharge line near pump using suitable clamps Risk of flooding Can cause personal injury and or property damage If a flexible discharge hose is used make sure pump is secured in sump to prevent movement Failure to secure pump may allow pump movement switch interference and prevent pump from starting or stopping 6 The switch is set to operate at these settings Sw...

Страница 6: ... damage Failure to make this operational check may lead to improper operation premature failure and flooding Operation Risk of electric shock Can shock burn or kill Do not handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water 1 Shaft seal depends on water for lubrication Do not operate pump unless it is submerged in water as seal may be damaged if allowed t...

Страница 7: ...fective float switch Replace float switch Restricted discharge obstacle or ice in piping Remove pump and clean pump and piping Float obstructed Remove obstruction Restricted intake screen Remove the pump and clean the intake screen and the impeller Pump operates but delivers little or no water Low line voltage If voltage under recommended minimum check size of wiring from main switch on property I...

Страница 8: ...and thread so it loosens to the right Step 3 Thread the new impeller onto the motor shaft as shown left hand thread tightens to the left Step 4 Re mount the motor on the base Be sure to mount it so that the switch is clear of the discharge and all other obstructions in the sump Last Run the pump through one complete cycle after it is assembled and reinstalled It should operate correctly and you sh...

Страница 9: ...6208 0410 Ref Part Description Qty Part Number 1 Power Cord Assembly 1 PW117 281 TSU 2 Impeller 1 PS5 33P 3 Vertical Float Switch Ass y 1 PKG208 NOTICE If motor fails replace entire pump See Impeller Replacement instructions ...

Страница 10: ... natación Informacion general sobre seguridad Las bombas de sumidero eléctricas por lo regular duran muchos años sin sufrir problemas de servicio cuando son instaladas mantenidas y usadas correctamente Sin embargo las situaciones inusuales interrupción del suministro eléctrico que va a la bomba tierra o suciedad en el sumidero inundación superior a la capacidad de la bomba fallas eléctricas y mecá...

Страница 11: ...zados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comuníquese con el Departamento de Atención al Cliente de CountyLine Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminación Si su bomba cloacal ha fallado Use guantes de caucho cuando manipule la bom...

Страница 12: ...o tiene agua o humedad en el piso no camine en el lugar mojado hasta que no haya cortado toda la energía eléctrica Si la llave de paso está en el sótano llame a la compañía eléctrica o a la compañía de electricidad para cortar el servicio a su casa o llame al departa mento de bomberos de su localidad para solicitar instrucciones Saque la bomba y repárela o reemplácela El incumplimiento de esta adv...

Страница 13: ...a tubería de descarga cerca de la bomba utilizando abrazaderas convenientes Riesgo de inundación Puede provocar lesiones personales y o daños materiales Si se usa una manguera de descarga flexible asegúrese de que la bomba esté bien inmobilizada para que no pueda moverse dentro del sumidero Si la bomba no está bien firme puede moverse y causar interferencia con el interruptor e impedir que la bomb...

Страница 14: ... El incumplimiento de esta verificación del funcionamiento puede resultar en funcionamiento impropio falla prematura e inundación Funcionamiento Riesgo de choque eléctrico Puede provocar choque quemadura o muerte No manipule la bomba o el motor de la bomba con las manos mojadas o cuando esté parado en suelo húmedo mojado o en el agua 1 La junta del eje depende del agua para su lubricación No haga ...

Страница 15: ...e el interruptor del flotante La bomba no se desconecta Interruptor defectuoso del flotante Reemplace el interruptor del flotante Descarga obstruida obstáculos o hielo en las tuberías Retire la bomba y limpie la bomba y la tubería El movimiento del flotante está obstruido Retire las obstrucciones Tamiz de admisión restringido Saque la bomba y limpie el tamiz de admisión y el impulsor La bomba func...

Страница 16: ... rosca izquierda de manera que se afloja hacia la derecha Paso 3 Enrosque el nuevo impulsor en el eje del motor según se ilustra rosca izquierda se aprieta hacia la izquierda Paso 4 Vuelva a montar el motor en la base Verifique que se haya colocado de manera que el interruptor quede despejado de la descarga y de toda otra obstrucción en el sumidero Por último Haga marchar la bomba por un ciclo com...

Страница 17: ...4 6208 0410 Ref Descripción Cant No de piezas 1 Unidad del cordón eléctrico 1 PW117 281 TSU 2 Impulsor 1 PS5 33P 3 Unidad del interruptor 1 PKG208 AVISO Si falla el motor reemplace toda la bomba Consulte la Reemplazar el impulsor ...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: