Installation 5

Cable Splicing

Splice cable to motor leads. Use one of the 

three methods outlined below. Use only copper 

wire for all connections. Use only UL

®

-approved 

water-submersion-grade electrical tape.
Taped splice - For wire sizes AWG 8 (8.4mm²) 

and larger:
1.  Cut off motor leads. Stagger lead and wire 

length so that 2nd lead is 2” (50mm) longer 

than 1st lead and 3rd lead is 2” (50mm) longer 

than second.

2.  Cut off cable ends. Be sure to match colors 

and lengths of wires in drop cable to colors 

and lengths of motor leads.

3.  Trim insulation back 1/2” (13mm) from cable 

ends and motor lead ends.

4.  Insert motor lead ends and cable ends into 

butt connectors (see Figure 2). Be sure to 

match wire colors between drop cable and 

motor leads.

5.  Using crimping pliers, indent butt connector 

lugs (see Figure 3) to secure wires.

6.  Cut electrical insulation putty into 3 equal 

parts and form tightly around butt connectors. 

Be sure electrical insulation putty overlaps 

insulated part of wire.

7.  Wrap each joint tightly with electrical tape - 

cover wire for about 1-1/2” (40mm) on each 

side of joint. Make four passes with the tape 

- when finished you should have four layers 

of tape tightly wrapped around the wire. Press 

edges of tape firmly down against the wire (see 

Figure 5).

 

NOTICE Since the tightly wound tape is the 

only means of keeping water out of the splice, 

the efficiency of the splice will depend on the 

care used in wrapping the tape.

 

NOTICE For wire sizes larger than AWG 8 

(8.4mm²), use a soldered joint rather than a 

butt connector (see Figure 4).

Heat-shrink splice - For wire sizes AWG 14, 12 

and 10 (2, 3, and 5.5mm²):
1.  Remove 3/8” (10mm) insulation from ends of 

motor leads and drop cable wires.

2.  Put plastic heat shrink tubing over motor leads.
3.  Match wire colors and lengths in drop cable to 

wire colors and lengths of motor leads.

4.  Insert cable and motor wire ends into butt 

connectors and crimp (See Figures 2 and 

3). BE SURE to match wire colors between 

drop cable and motor leads. Pull leads to 

check connections.

5.  Center tubing over butt connector and apply 

heat evenly with a torch (a match or lighter 

will not supply enough heat).

 

NOTICE Keep torch moving. Too much 

concentrated heat may damage tubing (see 

Figure 6).

1/2”

(12.7mm)

Butt Connector

Indent Here

Alternate Method

Twist and Solder

Completed Splice

6468 1111

Connector

Heat Shrink Tubing

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

Содержание 102814699

Страница 1: ...17 Installation Operation Parts For further operating installation or maintenance assistance Call 800 535 4950 English Pages 2 12 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionam...

Страница 2: ...st meet United States National Electrical Code Canadian Electrical Code and local codes as applicable for all wiring Disconnect electrical power supply before installing or servicing pump Make sure li...

Страница 3: ...carrying current to motor See Table 1 for recommended fuses and also see Cable Splicing Motor is supplied with copper ground wire Splice to copper conductor that matches motor wire size specified in...

Страница 4: ...AWG 5 3mm 8 AWG 8 4mm 6 AWG 13 3mm 4 AWG 21 1mm 3 AWG 26 7mm 2 AWG 33 6mm 1 AWG 42 4mm 0 AWG 53 5mm 115 1 2 110 33 174 53 278 85 440 134 685 209 1092 333 1373 419 1734 529 2184 666 2757 840 230 1 2 43...

Страница 5: ...ses with the tape when finished you should have four layers of tape tightly wrapped around the wire Press edges of tape firmly down against the wire see Figure 5 NOTICE Since the tightly wound tape is...

Страница 6: ...ed in designated location Most submersible motors will include a ground lead for connection Other motors will have designated location on motor bracket 4 Use only submersible cable supplied by pump ma...

Страница 7: ...pump or piping system to freeze may severely damage pump and will void warranty Protect pump and entire piping system including pressure tank from freezing Standard Tank Hookup See Figure 11 for pipi...

Страница 8: ...ntrol Pressure switch To house service Gate valve Relief valve 2 ft 6 m See table 6990 0915 Figure 11 Typical Standard Tank Installation Check Valve Distance to Top Bleeder Orifice Tank Size Gallon L...

Страница 9: ...ch To house service Gate valve Relief valve 2 ft 6 m See table 6990 0915 Figure 12 Typical Pre Charge Tank Installation Cut In PSI Cut Off PSI Pre charge Pressure 20 138 kPa 40 276 kPa 18 PSI 124 kPa...

Страница 10: ...hen motor is running Low or high voltage Check that line voltage is within 10 of rated nameplate voltage while motor is running If voltage variation is more than 10 call power company to adjust voltag...

Страница 11: ...e size against Cable Sizing tables Install larger wire from meter to pressure switch Install larger wire from pressure switch to pump If necessary have power company raise supply voltage Plugged intak...

Страница 12: ...l rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed car...

Страница 13: ...e instalar la bomba o de realizar tareas de reparaci n y mantenimiento Verifique que la tensi n de l nea y la frecuencia del suministro de corriente el ctrica coincidan con la tensi n y la frecuencia...

Страница 14: ...le El motor viene equipado con un cable de cobre de puesta a tierra Empalme este cable a tierra a un conductor de cobre que concuerde con el tama o del hilo del motor especificado en los Tabla 2 Conec...

Страница 15: ...5mm 115 1 2 110 33 174 53 278 85 440 134 685 209 1092 333 1373 419 1734 529 2184 666 2757 840 230 1 2 438 134 697 213 1112 339 1761 537 2740 835 4369 1332 5492 1674 6936 2114 8738 2663 11029 3362 3 4...

Страница 16: ...Es decir cuando termine tendr cuatro capas de cinta envueltas firmemente alrededor del cable Presione los bordes de la cinta firmemente contra el cable consulte la Figura 5 AVISO Debido a que la cinta...

Страница 17: ...otores sumergibles incluyen un conductor a tierra para la conexi n Otros motores tendr n un lugar designado en el soporte del motor 4 Use solamente cables sumergibles suministrados por el fabricante d...

Страница 18: ...as se congelen existe el riesgo de provocar da os graves en la bomba y esto invalidar la garant a Proteja la bomba y todo el sistema de tuber as incluyendo el tanque de presi n del congelamiento Cone...

Страница 19: ...a en pies m 42 159 2 6 82 310 4 3 9 120 454 2 5 1 5 Uni n V lvula de alivio V lvulas de compuerta Al servicio dom stico Man metro Interruptor de presi n Control del volumen de aire Desconector el ctri...

Страница 20: ...ing Tape cable to pipe Pump Ventilated well cap Submersible cable Union Electrical disconnect Pressure gauge Air volume control Pressure switch To house service Gate valve Relief valve 2 ft 6 m See ta...

Страница 21: ...ique que la tensi n de l nea est dentro de 10 de la tensi n nominal en la chapa de f brica cuando el motor est en marcha Si la variaci n de tensi n es mayor de 10 llame a la empresa de energ a el ctri...

Страница 22: ...en los Cuadros de Tama os de Cables Instale el hilo m s grande desde el contador al man stato Instale el hilo m s grande desde el man stato a la bomba De ser necesario haga que la empresa de energ a e...

Страница 23: ...productos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al...

Страница 24: ......

Отзывы: