Safety 2

Important Safety 

Instructions

SAVE THESE INSTRUCTIONS - This manual 

contains important instructions that should be 

followed during installation, operation, and 

maintenance of the product. 

 This is the 

safety alert symbol. When you see this symbol 

on your pump or in this manual, look for one 

of the following signal words and be alert to the 

potential for personal injury!

 indicates a hazard which, if not 

avoided, will result in death or serious injury.

 indicates a hazard which, if not 

avoided, could result in death or serious injury.

 indicates a hazard which, if not 

avoided, could result in minor or moderate injury.
NOTICE addresses practices not related to 

personal injury.
Carefully read and follow all safety instructions 

in this manual and on pump .
Keep safety labels in good condition. Replace 

missing or damaged safety labels.
California Proposition 65 Warning

 This product and related 

accessories contain chemicals known to the 

State of California to cause cancer, birth defects 

or other reproductive harm.

 Risk of electric shock . Can shock, 

burn or kill. To avoid dangerous or fatal electric 

shock hazard, use pump only in a water well.
•  Do not install this pump in any pond, river, or 

other open body of water that could be used 

for swimming or recreation. Do not swim, 

wade or play in a body of water in which a 

submersible pump has been installed.

•  Installation must meet United States National 

Electrical Code, Canadian Electrical Code, and 

local codes (as applicable) for all wiring.

•  Disconnect electrical power supply before 

installing or servicing pump.

•  Make sure line voltage and frequency of 

power supply match motor nameplate voltage 

and frequency.

 Risk of explosion . Under certain 

conditions, submersible pumps can develop 

extremely high pressure. Install a pressure 

relief valve capable of passing entire pump 

flow at 75 PSI (517 kPa) when using an air over 

water pressure tank. Install a pressure relief 

valve capable of passing entire pump flow at 

100 PSI (690 kPa) when using a pre-charged 

pressure tank.

 Risk of freezing . Do not allow 

pump, pressure tank, piping, or any other system 

component containing water to freeze. Freezing 

may damage system, leading to injury or 

flooding. Allowing pump or system components 

to freeze will void warranty.
1.  Install pump according to all plumbing, pump 

and well code requirements.

2.  Test well water for purity before using 

well. Call your local health department for 

testing procedure.

3.  During installation, keep well covered as much 

as possible to prevent leaves and foreign matter 

from falling into well. Foreign objects in well 

can contaminate the water and cause serious 

mechanical damage to the pump.

4.  Pipe joint compound can cause cracking in 

plastics. Use only PTFE pipe thread sealing 

tape when sealing joints in plastic pipe or 

when connecting pipe to thermoplastic pumps.

Specifications

Power supply required ....................... 115 or 230V, 60 Hz.
Liquid Temp. Range ......................... Less Than 86°F (30°C)
Discharge .......................................................1-1/4” FNPT

Содержание 102814699

Страница 1: ...17 Installation Operation Parts For further operating installation or maintenance assistance Call 800 535 4950 English Pages 2 12 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionam...

Страница 2: ...st meet United States National Electrical Code Canadian Electrical Code and local codes as applicable for all wiring Disconnect electrical power supply before installing or servicing pump Make sure li...

Страница 3: ...carrying current to motor See Table 1 for recommended fuses and also see Cable Splicing Motor is supplied with copper ground wire Splice to copper conductor that matches motor wire size specified in...

Страница 4: ...AWG 5 3mm 8 AWG 8 4mm 6 AWG 13 3mm 4 AWG 21 1mm 3 AWG 26 7mm 2 AWG 33 6mm 1 AWG 42 4mm 0 AWG 53 5mm 115 1 2 110 33 174 53 278 85 440 134 685 209 1092 333 1373 419 1734 529 2184 666 2757 840 230 1 2 43...

Страница 5: ...ses with the tape when finished you should have four layers of tape tightly wrapped around the wire Press edges of tape firmly down against the wire see Figure 5 NOTICE Since the tightly wound tape is...

Страница 6: ...ed in designated location Most submersible motors will include a ground lead for connection Other motors will have designated location on motor bracket 4 Use only submersible cable supplied by pump ma...

Страница 7: ...pump or piping system to freeze may severely damage pump and will void warranty Protect pump and entire piping system including pressure tank from freezing Standard Tank Hookup See Figure 11 for pipi...

Страница 8: ...ntrol Pressure switch To house service Gate valve Relief valve 2 ft 6 m See table 6990 0915 Figure 11 Typical Standard Tank Installation Check Valve Distance to Top Bleeder Orifice Tank Size Gallon L...

Страница 9: ...ch To house service Gate valve Relief valve 2 ft 6 m See table 6990 0915 Figure 12 Typical Pre Charge Tank Installation Cut In PSI Cut Off PSI Pre charge Pressure 20 138 kPa 40 276 kPa 18 PSI 124 kPa...

Страница 10: ...hen motor is running Low or high voltage Check that line voltage is within 10 of rated nameplate voltage while motor is running If voltage variation is more than 10 call power company to adjust voltag...

Страница 11: ...e size against Cable Sizing tables Install larger wire from meter to pressure switch Install larger wire from pressure switch to pump If necessary have power company raise supply voltage Plugged intak...

Страница 12: ...l rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed car...

Страница 13: ...e instalar la bomba o de realizar tareas de reparaci n y mantenimiento Verifique que la tensi n de l nea y la frecuencia del suministro de corriente el ctrica coincidan con la tensi n y la frecuencia...

Страница 14: ...le El motor viene equipado con un cable de cobre de puesta a tierra Empalme este cable a tierra a un conductor de cobre que concuerde con el tama o del hilo del motor especificado en los Tabla 2 Conec...

Страница 15: ...5mm 115 1 2 110 33 174 53 278 85 440 134 685 209 1092 333 1373 419 1734 529 2184 666 2757 840 230 1 2 438 134 697 213 1112 339 1761 537 2740 835 4369 1332 5492 1674 6936 2114 8738 2663 11029 3362 3 4...

Страница 16: ...Es decir cuando termine tendr cuatro capas de cinta envueltas firmemente alrededor del cable Presione los bordes de la cinta firmemente contra el cable consulte la Figura 5 AVISO Debido a que la cinta...

Страница 17: ...otores sumergibles incluyen un conductor a tierra para la conexi n Otros motores tendr n un lugar designado en el soporte del motor 4 Use solamente cables sumergibles suministrados por el fabricante d...

Страница 18: ...as se congelen existe el riesgo de provocar da os graves en la bomba y esto invalidar la garant a Proteja la bomba y todo el sistema de tuber as incluyendo el tanque de presi n del congelamiento Cone...

Страница 19: ...a en pies m 42 159 2 6 82 310 4 3 9 120 454 2 5 1 5 Uni n V lvula de alivio V lvulas de compuerta Al servicio dom stico Man metro Interruptor de presi n Control del volumen de aire Desconector el ctri...

Страница 20: ...ing Tape cable to pipe Pump Ventilated well cap Submersible cable Union Electrical disconnect Pressure gauge Air volume control Pressure switch To house service Gate valve Relief valve 2 ft 6 m See ta...

Страница 21: ...ique que la tensi n de l nea est dentro de 10 de la tensi n nominal en la chapa de f brica cuando el motor est en marcha Si la variaci n de tensi n es mayor de 10 llame a la empresa de energ a el ctri...

Страница 22: ...en los Cuadros de Tama os de Cables Instale el hilo m s grande desde el contador al man stato Instale el hilo m s grande desde el man stato a la bomba De ser necesario haga que la empresa de energ a e...

Страница 23: ...productos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al...