Troubleshooting 10

Problem

Check

Corrective Action

Motor will not start but fuses do not blow .

No voltage.

No voltage at fuse box.

Consult power supplier, check generator.

No voltage at pressure switch.

Check connections, rewire from supply to 

pressure switch.

No voltage on load side of pressure 

switch.

Check connections, replace pressure 

switch.

Cable or splices bad.

Consult serviceman or licensed electrician.

Fuses blow or overload protector trips when motor starts .
Wrong size fuse or 

wrong size time delay 

fuse.

Check fuse size against Fuse Size 

tables.

Install correct fuse or time delay fuse.

Wire size too small.

Check wire size against Cable Sizing 

tables.

Install correct size wire.

Low or high voltage.

Check that line voltage is within 

±10% of nameplate rated voltage 

while motor is running.

If voltage variation is greater than ±10%, 

call power company to adjust voltage.

Pump or motor stuck or 

binding.

Check for locked rotor in pump.

If necessary, pull pump (make all possible 

above ground checks first). If pump is 

locked, replace it. Clean well of all sand or 

lime before reinstalling pump.

Fuses blow or overload protector trips when motor is running .

Low or high voltage.

Check that line voltage is within 

±10% of rated nameplate voltage 

while motor is running.

If voltage variation is more than ±10%, call 

power company to adjust voltage.

Wire size too small.

Check wire size against Cable Sizing 

tables.

Install correct wire size.

Cable splices or motor 

leads grounded, 

shorted, or open.

Consult licensed electrician or 

qualified serviceman.

Do not attempt to disassemble pump or 

motor.

Pump starts too frequently .

Leaks in system.

Check all tank connections with 

soapsuds for air leaks. Check 

plumbing for leaks.

System must be air and water tight.

Pressure switch.

Check for defective switch or switch 

out of adjustment.

Re-adjust or replace pressure switch.

Tank waterlogged.

Pre-charged tanks; check tank pre-

charge air pressure, check for leak in 

bladder.

Air over water tanks: repair or replace 

tanks; replace air pressure valve if 

necessary.

Air over water tanks: check for air 

leaks. Check Air Volume Control 

(AVC). Check air pressure valve 

operation.

Air over water tanks: repair or replace 

tanks; replace air pressure valve if 

necessary.

Leak in drop pipe.

Raise drop pipe one length at a time 

until water stands in pipe.

Replace pipe above that point.

Pressure switch too far 

from tank.

Measure distance from pressure 

switch to tank.

Move switch to within one foot (.3m) of 

tank.

Содержание 102814699

Страница 1: ...17 Installation Operation Parts For further operating installation or maintenance assistance Call 800 535 4950 English Pages 2 12 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionam...

Страница 2: ...st meet United States National Electrical Code Canadian Electrical Code and local codes as applicable for all wiring Disconnect electrical power supply before installing or servicing pump Make sure li...

Страница 3: ...carrying current to motor See Table 1 for recommended fuses and also see Cable Splicing Motor is supplied with copper ground wire Splice to copper conductor that matches motor wire size specified in...

Страница 4: ...AWG 5 3mm 8 AWG 8 4mm 6 AWG 13 3mm 4 AWG 21 1mm 3 AWG 26 7mm 2 AWG 33 6mm 1 AWG 42 4mm 0 AWG 53 5mm 115 1 2 110 33 174 53 278 85 440 134 685 209 1092 333 1373 419 1734 529 2184 666 2757 840 230 1 2 43...

Страница 5: ...ses with the tape when finished you should have four layers of tape tightly wrapped around the wire Press edges of tape firmly down against the wire see Figure 5 NOTICE Since the tightly wound tape is...

Страница 6: ...ed in designated location Most submersible motors will include a ground lead for connection Other motors will have designated location on motor bracket 4 Use only submersible cable supplied by pump ma...

Страница 7: ...pump or piping system to freeze may severely damage pump and will void warranty Protect pump and entire piping system including pressure tank from freezing Standard Tank Hookup See Figure 11 for pipi...

Страница 8: ...ntrol Pressure switch To house service Gate valve Relief valve 2 ft 6 m See table 6990 0915 Figure 11 Typical Standard Tank Installation Check Valve Distance to Top Bleeder Orifice Tank Size Gallon L...

Страница 9: ...ch To house service Gate valve Relief valve 2 ft 6 m See table 6990 0915 Figure 12 Typical Pre Charge Tank Installation Cut In PSI Cut Off PSI Pre charge Pressure 20 138 kPa 40 276 kPa 18 PSI 124 kPa...

Страница 10: ...hen motor is running Low or high voltage Check that line voltage is within 10 of rated nameplate voltage while motor is running If voltage variation is more than 10 call power company to adjust voltag...

Страница 11: ...e size against Cable Sizing tables Install larger wire from meter to pressure switch Install larger wire from pressure switch to pump If necessary have power company raise supply voltage Plugged intak...

Страница 12: ...l rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed car...

Страница 13: ...e instalar la bomba o de realizar tareas de reparaci n y mantenimiento Verifique que la tensi n de l nea y la frecuencia del suministro de corriente el ctrica coincidan con la tensi n y la frecuencia...

Страница 14: ...le El motor viene equipado con un cable de cobre de puesta a tierra Empalme este cable a tierra a un conductor de cobre que concuerde con el tama o del hilo del motor especificado en los Tabla 2 Conec...

Страница 15: ...5mm 115 1 2 110 33 174 53 278 85 440 134 685 209 1092 333 1373 419 1734 529 2184 666 2757 840 230 1 2 438 134 697 213 1112 339 1761 537 2740 835 4369 1332 5492 1674 6936 2114 8738 2663 11029 3362 3 4...

Страница 16: ...Es decir cuando termine tendr cuatro capas de cinta envueltas firmemente alrededor del cable Presione los bordes de la cinta firmemente contra el cable consulte la Figura 5 AVISO Debido a que la cinta...

Страница 17: ...otores sumergibles incluyen un conductor a tierra para la conexi n Otros motores tendr n un lugar designado en el soporte del motor 4 Use solamente cables sumergibles suministrados por el fabricante d...

Страница 18: ...as se congelen existe el riesgo de provocar da os graves en la bomba y esto invalidar la garant a Proteja la bomba y todo el sistema de tuber as incluyendo el tanque de presi n del congelamiento Cone...

Страница 19: ...a en pies m 42 159 2 6 82 310 4 3 9 120 454 2 5 1 5 Uni n V lvula de alivio V lvulas de compuerta Al servicio dom stico Man metro Interruptor de presi n Control del volumen de aire Desconector el ctri...

Страница 20: ...ing Tape cable to pipe Pump Ventilated well cap Submersible cable Union Electrical disconnect Pressure gauge Air volume control Pressure switch To house service Gate valve Relief valve 2 ft 6 m See ta...

Страница 21: ...ique que la tensi n de l nea est dentro de 10 de la tensi n nominal en la chapa de f brica cuando el motor est en marcha Si la variaci n de tensi n es mayor de 10 llame a la empresa de energ a el ctri...

Страница 22: ...en los Cuadros de Tama os de Cables Instale el hilo m s grande desde el contador al man stato Instale el hilo m s grande desde el man stato a la bomba De ser necesario haga que la empresa de energ a e...

Страница 23: ...productos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al...

Страница 24: ......

Отзывы: