6
INSTALLATION
Your furnace is designed to be added on to existing duct
work and operate either with or without another heat
source such as a gas furnace. The following diagrams
illustrate acceptable ways of ducting your furnace.
Clearance To Combustible Materials
Your Furnace has been tested to determine the SAFE
clearances to combustible material. The clearances are
printed on the label located on the back of the furnace.
The chart on this page also states these minimum clear-
ances. Make sure you follow these when choosing your
furnace location.
Any hot air plenum connection to a furnace must be con-
structed of metal.
Clearance to
Combustibles
Furnace to back wall
30”
Furnace to side wall
12”
Pipe to back wall
18”
Pipe to side wall
18”
Furnace to ceiling
30”
Ductwork to ceiling
18-6-1”
NOTE: INSTALL ONLY ON A NON-COMBUSTIBLE FLOOR.