5
EN
G
LI
S
H
Fig. 3A
Fig. 3B
Fig. 3C
Fig. 4
8. Fix the light to the wall bracket; tighten all screws and lock nuts. Position the floodlight
in the desired place.
9. Replace the fuse and adjust the light pattern.
Important!
Undo lock nuts and screws before adjusting the angle of the light.
Warning:
This light must NOT be directed at flammable surfaces (Fig. 3B,C).
Controls
• Operating time after activation the illumination time can be adjusted from (10±5 seconds)
to (4±1 minutes), this time is altered by turning the [TIME] dial + or –.
Note!
Each time
the detector senses a movement the operating time starts again.
• The light sensitivity needed for activation is measured by a photocell which differentiates
between light and dark. Adjust it by turning the [LUX] dial from
Sun
to
Moon
.
Sun
is
used during the day until nightfall;
Moon
is only used at night, in the dark.
• The motion sensitivity is controlled by the [SENS] dial, which alters the distance needed
between the sensor and the motion in order to activate the light. Turn the dial towards
the (+) to increase the distance needed, and the opposite way to lessen the distance
needed to activate the light.
+/-4 degrees
At least 90 degrees
At least 1 m
At least
20 cm