background image

4

1 - GENERAL SAFETY WARNINGS

Installation, modifications

The installation must be carried out by professionally 

qualified  people,  in  compliance  with  national  and  local 

regulations, as well as with the instructions given in this 

manual.

Incorrect installation or bad maintenance can cause injury 

or damage to people, animals or things, for which the 

manufacturer cannot be held responsible.

A domestic hot water temperature of higher than 51°C 

can cause injury or damage, even of a permanent nature, 

to people, animals and things. In particular, children, the 

elderly and the disabled must be protected against any 

possible risks of scalds, by inserting devices that limit the 

temperature of use of the DHW to users.

Do not leave packaging and replacement parts within 

reach of children.

The user, in line with the arrangements for use, is obliged 

to maintain the system in good order and to guarantee 

reliable and safe operation of the equipment.

The user is obliged to have maintenance of the system 

carried out according to national and local regulations 

and according to the arrangements of this brochure, by a 

professionally qualified engineer.

Before performing any cleaning or maintenance operations, 

disconnect the storage tank from the mains power supply 

and/or activate the relevant isolation devices.

After completing any cleaning or maintenance operation, 

before reconnecting the electric power supply, make sure 

that all the internal parts of the storage tank have been 

properly dried.

This storage tank cannot be used by people (including 

children) with reduced physical, sensorial or mental 

capacities or with little experience and knowledge unless 

they are tested and instructed on the use of the storage 

tank by the person responsible for their safety.

This brochure is an integral and essential part of the product 

and must be retained carefully by the user for possible 

future reference. If the storage tank has to be replaced or 

if you have to move and leave behind the storage tank for 

another user, always make sure that this brochure is left 

for the new user and/or installer. 

Any eventual optional extras or kits added later must be 

Cosmogas originals.

This storage tank must be used only for the purpose for 

which it was expressly intended: the storage of hot water 

for domestic and sanitary uses for civil use.

The constructor bears no contractual or non-contractual 

responsibility for damage caused by errors in the installation 

or use and also where the instructions given by the 

manufacturer himself, or the applicable national and local 

laws, are not observed.

For reasons of safety and environmental protection, the 

various pieces of packaging must be disposed of in suitable 

recycling centres.

In the event of a fault

In the event of a fault and/or poor operation of the storage 

tank, disconnect it and do not attempt to carry out any repair. 

Contact only a professionally qualified engineer. If components 

need to be replaced, these must be original spare parts. 

Should this be ignored, the safety of the equipment may be 

compromised.

Professionally qualified engineer

.

By professionally qualified engineer we mean someone having 

specific technical skills in the sector of components of systems 

for heating and the production of hot water for hygienic and 

sanitary uses in a civil context, electrical systems, and systems 

for the use of exhaust gases. Such people must have the skills 

envisaged by the law.

Technical drawings

All the drawings shown in this manual, relating to electrical, 

hydraulic or gas installation systems, must be understood to 

be purely illustrative. All the safety devices, auxiliary devices 

as well as the diameters of the electrical, hydraulic and gas 

pipes, must always be checked by a professionally qualified 

engineer, to make sure they satisfy the applicable laws and 

regulations.

1.1 - National installation laws

Respect the national regulations, provisions, directives and 

laws in force.

- Ministerial Decree of 22/01/2008 n°37 (Ex Law of 05/03/90 

n°46)

- CEI standard 64-8

Содержание AGUAstore 1000

Страница 1: ...62403763 R00 18 03 2021_UK INSTALLATION USE AND MAINTENANCE MANUAL AGUAstore STORAGE TANKS...

Страница 2: ......

Страница 3: ...with AGUADENS 37 18 5 9 Hydraulic connection with solar assembly upon request 20 5 10 System sensors identification and positioning 21 5 12 Electrical connections 22 5 12 1 Connecting power supply cab...

Страница 4: ...torage tank has to be replaced or if you have to move and leave behind the storage tank for another user always make sure that this brochure is left for the new user and or installer Any eventual opti...

Страница 5: ...amage to people animals or things Generic danger If these warnings are not heeded it can jeopardise correct operation of the equipment or cause serious injury or damage to people animals or things Sym...

Страница 6: ...ided to facilitate the draining of the storage tank to be taken care of by the installer 1 Solar supply 1 2 Solar return 1 3 Upper coil supply 1 4 Upper coil return 1 5 Sensor door 6 Hot water outlet...

Страница 7: ...installer 1 Solar supply 1 2 Solar return 1 3 Upper coil supply 1 4 Upper coil return 1 5 Sensor door 6 Hot water outlet 2 7 Cold water inlet 2 8 Recirculation 2 9 Electronic anode 1 2 10 11 Hot wate...

Страница 8: ...aller 1 Solar supply 1 2 Solar return 1 3 Upper coil supply 1 4 Upper coil return 1 5 Sensor door 6 Hot water outlet 2 7 Cold water inlet 2 8 Recirculation 2 9 Electronic anode 1 2 10 11 Hot water hea...

Страница 9: ...ller 1 Solar supply 1 2 Solar return 1 3 Upper coil supply 1 4 Upper coil return 1 5 Sensor door 6 Hot water outlet 2 7 Cold water inlet 2 8 Recirculation 2 9 Electronic anode 1 2 10 11 Hot water heat...

Страница 10: ...sensor from hot water heater 9 DHW uses 10 11 Domestic cold water inlet 12 13 14 15 16 17 18 19 20 Expansion tank provision the responsibility of the installer 21 22 Remote control on request 23 Solar...

Страница 11: ...18 INAIL maximum pressure switch on request 19 INAIL safety thermostat on request 20 Expansion tank provision the responsibility of the installer 21 22 Remote control on request 23 Solar control unit...

Страница 12: ...itions HEATING COILS AVAILABLE OUTPUT CAPACITY litres UPPER COIL EXCHANGED OUTPUT kW 300 5 500 9 800 14 1000 14 Conditions Water storage tank temperature 65 C t supply and return 15 C Supply temperatu...

Страница 13: ...itions HEATING COILS AVAILABLE OUTPUT CAPACITY litres TWO COILS EXCHANGED OUTPUT kW 300 9 500 14 800 20 1000 23 Conditions Water storage tank temperature 65 C t supply and return 15 C Supply temperatu...

Страница 14: ...control on request 23 Solar control unit on request 24 S2 bottom storage tank sensor from solar control unit 25 Solar safety and charge group on request 26 Solar panels on request 27 28 29 30 31 Stora...

Страница 15: ...ol unit on request 24 S2 bottom storage tank sensor from solar control unit 25 Solar safety and charge group on request 26 Solar panels on request 27 28 29 30 31 Storage tank safety valve 32 Isolation...

Страница 16: ...er supply of electronic anode responsibility of installer As far as the hot water heater s connections are concerned see the instructions in its installation manual This unit must be installed in a pl...

Страница 17: ...UADENS 16 22 For hydraulic connection between the storage tank and the AGUADENS 16 and 22 model units a specific KIT can be requested model 300 AGUADENS 16 22 62660030 models 500 800 1000 AGUADENS 16...

Страница 18: ...5 8 Hydraulic connection with AGUADENS 37 For hydraulic connection between the storage tank and the AGUADENS 37 model units a specific KIT can be requested model 300 AGUADENS 37 62630261 model 500 800...

Страница 19: ...19 5 INSTALLATION 62630260_004 4 62630260_005 5 Figure 5 6 Pipe installation stages AGUADENS 37 continued from previous page...

Страница 20: ...solar assembly upon request Proceed with making the connection as shown see Figure 5 7 For the electrical connections follow the instructions in the solar assembly 62630260_006 Figure 5 7 Installation...

Страница 21: ...led on the cold water inlet WARNING If the hot water heater has to work at temperatures above 60 C the hardness of the water must be less than 15 F 150 mg l WARNING The water must not be softened to v...

Страница 22: ...rown cable Live to terminal 1 L1 7 Connect the blue cable Neutral to terminal 2 N 5 12 2 Hot water heater connection To connect the hot water heater proceed as follows refer to Figure 5 9 WARNING Disc...

Страница 23: ...Live to terminal 7 L 7 Connect the blue cable Neutral to terminal 8 N 8 For the connection of the other end of the cable to the hot water heater refer to the installation manual supplied with the sola...

Страница 24: ...Water heater 5 Possible solar group 6 Possible auxiliary pump heating circuit 7 Possible auxiliary pump control thermostat heating circuit Figure 5 10 Multi wire wiring diagram 8 Storage tank sensor S...

Страница 25: ...am Figure 5 11 Operational wiring diagram 1 Power supply 2 Electrical connection panel 3 Electronic anode 4 Water heater 5 Possible solar group 6 Possible auxiliary pump heating circuit 7 Possible aux...

Страница 26: ...not being used the system must be emptied proceeding as follows Follow the procedure to empty the domestic hot water circuit described in section 7 1 2 6 7 Anti frost precautions WARNING The anti fros...

Страница 27: ...ot connected Check the metal part of the anode is not in con tact with the metal parts of the storage tank Check the connection of the anode Check it is correctly earthed Table of electronic anode ope...

Страница 28: ...r content l 4 2 Lower coil exchange surface m2 1 2 Lower coil water content l 8 4 Material for outer cover PVC Material for lid ABS Colour of outer cover White Colour of lid Black Material for insulat...

Страница 29: ...1 2 1 8 1 8 8 4 12 6 12 6 1 8 2 4 3 0 12 6 16 8 21 0 PVC PVC PVC ABS ABS ABS White White White Black Black Black Rigid PU foam CFC free Polyester fibre class M1 B1 Polyester fibre class M1 B1 50 100...

Страница 30: ...Low Voltage 2014 35 UE and Electromagnetic Compatibility 2014 30 UE Monitoring of the product was carried out by the body shown on form C The warranty number corresponds to the registration number Th...

Страница 31: ......

Страница 32: ...COSMOGAS s r l Via L da Vinci 16 47014 MELDOLA FC ITALY info cosmogas com www cosmogas com...

Отзывы: