14
15
INSTALLATION INSTRUCTIONS
6.
6a.
Drill a
5
- 1/4” Round Hole into the bottom of the cabinet.
(skip this step for
recirculating mode)
6
b
.
Drill a 1 - 1/2” hole into the bottom of the cabinet for the Electrical Access hole
according to the location of electrical wires shown on
page 5
of this manual
.
6
c
. Pull the round duct
through the bottom of the
new cabinet holes
(
skip this step for
recirculating mode).
7. Lift the hood and hang the hood unit on the back wall using the screws drilled in Step 3.
8.
Once the hood is
securely
hung to the back wall, remove the aluminum filters from underneath
the
hood.
9. Drill
four
pieces of
ST4*16
wood screws (
Part
E
) into the bottom of the cabinet
using the
four screw holes at the top of the hood.
Once the hood is secured into the cabinet tighten the wood screws located in the back
of the hood.
Re-install the filters. Reconnect unit to power source.
Step 7
Step 8-9
Step 6
ELECTRICAL
ACCESS HOLE
5.25"
6
d
. Pull the
electrical cord
through the bottom of the
cabinet holes.
RECIRCULATING CARBON FILTERS
SKIP THIS PAGE IF YOU ARE INSTALLING A DUCTED RANGE
HOOD. C
ARBON
FILTERS ARE ONLY INCLUDED WITH
DUCTLESS MODELS.
Installing Recirculating Filters (For Ductless
installation
Only)
1. Remove the Aluminum Filters.
2. The charcoal filter is installed to the motor housing as
shown. Line up the filter over the center of the motor
housing, then turn the filter until the side tabs fit into
slots and locks in place.
3. To replace the carbon filter reverse the process and repeat
.
THE CARBON FILTER MUST BE REPLACED EVERY 4-6 MONTHS
DEPENDING ON USE. ADDITIONAL ALUMINUM OR CHARCOAL
FILTERS CAN BE PURCHASED FROM:
WWW.COSMOAPPLIANCES.COM
Charcoal Filter Part # - CFK3-
T
M