Location Requirements
IMPORTANT:
Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the installer’s
responsibility to comply with installation clearances specified on the
model/serial/rating plate. The model/serial rating plate is located inside the
range hood on the rear wall of the range hood.
Range hood location should be away from strong draft areas, such as
windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given dimensions
provide minimum clearance. Consult your cooktop/range manufacturer
installation instructions before making any cutouts.
Grounded electrical outlet is required. See the "Electrical Requirements"
section.
The range hood is factory set for venting through the roof or wall. For ductless
(recirculating) installations see "Ductless (Recirculating) Installation Through
the Soffit/Cabinet" in the "Prepare Location" section. Charcoal filters are
required for ductless (recirculating) installations. See "Optional Parts" in the
"Tools and Parts" section to order.
All openings in ceiling and wall where range hood will be installed must be
sealed.
For Mobile Home Installations:
The installation of this range hood must conform to the Manufactured Home
Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal
Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280)
or when such standard is not applicable, the standard for Manufactured
Home Installation 1982 (Manufactured Home Sites, Communities and Setups)
ANSI A225.1/NFPA 501A or latest edition, or with local codes.