n
When a non-regulated source is used as a front end, make sure
that the voltage fluctuation together with the ripple voltage will not
exceed the input voltage range.
n
Select the converter that is able to handle the start-up current (Ip).
n
n
n
When too much stress is applied on the input/output pins of the
unit, the internal connection may be weakened. As below Fig. 9.1,
avoid applying stress of more than 19.6N (2kgf) on the pins hori-
zontally and more than 39.2N (4kgf) vertically.
The input/output pins are soldered on PCB internally, therefore,
do not pull or bend them with abnormal forces.
When additional stress is expected to be put on the input/output
pins because of vibration or impacts, fix the unit on PCB (using sil-
icone rubber or fixing fittings) to reduce the stress onto the in-
put/output pins.
ZU/ZT-39
ZU1R5 ZU3 ZU6 ZU10
6 Input Voltage/
Current Range
Fig.6.1 Input current characteristics
7 Cleaning
n
Cleaning is possible by below listed conditions.
No.
Classification
1
2
3
4
Cleaning agents
Pine Alpha ST–100S(ARAKAWA CHEMICAL CO.)
Clean Through 750H(KAO Corporation)
IPA
Asahiklin AK–225AES(ASAHI GLASS CO.)
Water type
Solvent type
No.
1
2
3
4
Cleaning method
Liquid Temp.
Varnishing or Ultra
sonic wave
Less than
60
Period
Within 5
minutes
Within 2
minutes
–
Varnishing,Ultra sonic
wave, Vapor
Cleaning method
n
During cleaning to drying (the condition that cleaning liquid is
soaked into the ink of name plate), do not touch on the surface of
name plate.
n
After cleaning, dry them enough.
8 Soldering
n
Flow soldering : 260
less than 15 seconds.
n
Soldering iron : 450
less than 5 seconds.
9 Input/Output Pin
Fig.9.1 Stress onto the pins
n
It is possible to supply the pulse current for the pulse load by con-
necting the capacitor externally at the output side.
10 Peak Current
(Pulse Load)
ZU/ZT
Instruction
anual
M