1 Pin Connection
l
Single Output
ZU/ZT-40
ZU15 ZU25
No. Pin connection
Function
+DC INPUT
-DC INPUT
RC
+DC OUTPUT
COMMON
-DC OUTPUT
TRM
+Side of input voltage
-Side of input voltage
Remote ON/OFF
+Side of output voltage
GND of output voltage (Only applicable for Dual output)
-Side of output voltage
Adjustment voltage range
l
Dual (±) Output
2 Function
2.1 Input voltage
n
n
If the wrong input is applied, the unit will not operate properly
and/or may be damaged.
Overcurrent protection circuit is built-in and comes into effect at
over 105% of the rated current.
Overcurrent protection prevents the unit from short circuit and
over current condition of less than 20 sec.
The unit automatically recovers when the fault condition is
cleared.
2.2 Overcurrent protection
ZU/ZT
n
The average current Iav of output is shown in below formula.
(Iop - Is) t
T
Iav = Is +
n
The required electrolytic capacitor C is found by below formula.
(Iop - Iav) t
Vo
C =