background image

3.1 Installation method

¡

This power supply is manufactured by SMD technology.

The stress to P.C.B like twisting or bending causes the defect of 

the unit,so handle the unit with care.

¡

In case of metal chassis, keep the distance between d

1

 & d

2

 for to 

insulate between lead of component and metal chassis, use the 

spacer of 8mm or more between d

1

. If it is less than d

1

 & d

2

, insert 

the insulation sheet between power supply and metal chassis.

3.2 Derating

¡

The operative ambient temperature is different by with / without 

chassis cover or mounting position. Please refer drawings as below.

Note:  In the hatched area, the specification of Ripple, Ripple 

Noise is different from other area.

¿ 

LGA50A-3R3-Y, -5, -12, -15

¿ 

LGA50A-3R3-Y, -5, -12, -15 -SN

    (with Chassis & Cover)

¿ 

LGA50A-24, -48

¿ 

LGA50A-24, -48 -SN (with Chassis & Cover)

¿ 

LGA75A

¿ 

LGA75A-

O

-SN (with Chassis & Cover)

¿ 

LGA100A

3  

Assembling and 
Installation Method

-10

70

60

50

40

30

1

1

2

2

Forced air (0.5m

3

/ min)

1

Convection

80

100

60

40

20

0

20

10

0

Load

factor

[%

]

[

C

]

Ambient temperature 

(A)mountin

1

(E)mounting

g

(B), (C), (D)mounting

(A) ~ (F)
mounting

-10

70

60

50

40

30

1

1

2

2

1

Convection

80

100

60

40

20

0

20

10

0

Load

factor

[%

]

[

C

]

Ambient temperature 

(A)mountin

1

(E)mounting

g

(B), (C), (D)mounting

(A) ~ (F)
mounting

Forced air (0.5m

3

 / min)

-10

70

60

50

40

30

1

1

2

2

Forced air (0.5m

3

/ min)

1

Convection

80

100

60

40

20

0

20

10

0

Load

factor

[%

]

[

C

]

Ambient temperature 

(D)mounting

(E)mounting

(A) ~ (F)
mounting

1

1

(A)mounting

(B), (C)mounting

-10

70

60

50

40

30

2

2

1

Convection

80

100

60

40

20

0

20

10

0

Load

factor

[%

]

[

C

]

Ambient temperature 

(A) ~ (F)
mounting

Forced air (0.5m

3

 / min)

1

1

(D)mounting

(E)mounting

1

(C)mounting

1

1

(A)mounting

(B)mounting

-10

70

60

50

40

30

1

1

2

2

1

Convection

80

100

60

40

20

0

20

10

0

Load

factor

[%

]

[

C

]

Ambient temperature 

(A)mountin

1

(E)mounting

g

(B), (C), (D)mounting

(A) ~ (F)
mounting

Forced air (0.5m

3

 / min)

AC-DC Power Supplies Open Frame/ Enclosed Type

Instruction Manual

LGA-15

LGA

*

 [F] mounting should be operated by Forced air.

*

 [F] mounting should be operated by Forced air.

*

 [F] mounting should be operated by Forced air.

*

 [F] mounting should be operated by Forced air.

*

 [F] mounting should be operated by Forced air.

Fig.3.1 Installation method

Fig.3.2 Ambient temperature derating curve

Fig.3.3 Ambient temperature derating curve

*

 [F] mounting should be operated by Forced air.

*

 [F] mounting should be operated by Forced air.

Fig.3.4 Ambient temperature derating curve

Fig.3.5 Ambient temperature derating curve

Fig.3.6 Ambient temperature derating curve

Fig.3.7 Ambient temperature derating curve

Fig.3.8 Ambient temperature derating curve

-10

70

60

50

40

30

1

1

2

2

Forced air (0.5m

3

/ min)

1

Convection

80

100

60

40

20

0

20

10

0

Load

factor

[%]

[

C

]

Ambient temperature 

(C), (E)mounting

(D)mounting

(A) ~ (F)
mounting

1

1

(A)mounting

(B)mounting

-10

70

60

50

40

30

1

1

2

2

Forced air (0.5m

3

/ min)

1

Convection

80

100

60

40

20

0

20

10

0

Load

factor

[%]

[

C

]

Ambient temperature 

(A)mounting

(B), (C), (D)mounting

1

(E) mounting

(A) ~ (F)
mounting

=

=

8mm min

4mm min

CN1

CN1

d

2

d

1

d

2

d

2

d

2

d

2

d

2

me̲lga1.indd   LGA-15

me lga1 indd LGA-15

2015/06/19   14:42:26

2015/06/19 14:42:26

Содержание LGA100A

Страница 1: ...ethod Forward Converter Forward Converter Forward Converter 1 A 3 6 2 4 1 7 1 3 current Input 130 operation availability 2 Series Parallel Parallel operation SCR CEM 3 Yes Yes PCB Pattern SCR SCR Ther...

Страница 2: ...Series Operation and Parallel Operation LGA 14 1 1 Input voltage range 1 2 Inrush current limiting 1 3 Overcurrent protection 1 4 Overvoltage protection 1 5 Output voltage adjustment range 1 6 Isolat...

Страница 3: ...input should be shut down if overvoltage protection is in operation The mini mum interval of AC recycling for recovery is 1 5 minutes LGA240A is 3minutes The recovery time varies depending on input v...

Страница 4: ...ing E mounting A F mounting 1 1 A mounting B C mounting 10 70 60 50 40 30 2 2 1Convection 80 100 60 40 20 0 20 10 0 Load factor C Ambient temperature A F mounting Forced air 0 5m3 min 1 1 D mounting E...

Страница 5: ...ounting AC DC Power Supplies Open Frame Enclosed Type Instruction Manual LGA 16 LGA F mounting should be operated by Forced air Fig 3 14 Derating curve depending on input voltage Fig 3 9 Ambient tempe...

Страница 6: ...66 77 Io 40 75 81 A B C D E F Forced air 70 Io 100 85 80 Io 70 80 75 Table 3 4 Temperatures of Point A Point B LGA100A O Mounting Method Cooling Method Load factor Max temperature Point A C Point B C...

Страница 7: ...50C 5years 3years Warranty Table 3 13 Warranty LGA50A 3R3 Y 5 12 15 Mounting Method Cooling Method Average ambient temperature year Load factor Io 75 75 Io 100 A Convection Ta 40C or less 5years 5yea...

Страница 8: ...able 3 18 Warranty LGA240A O Mounting Method Cooling Method Average ambient temperature year Load factor Io 75 75 Io 100 A Convection Ta 30C or less 5years 5years Ta 40C 5years 3years B C Convection T...

Страница 9: ...se the output voltage turn a built in potentiometer clockwise To decrease the output voltage turn it counterclockwise Please take care when you adjust output voltage by potentiometer because there is...

Отзывы: