COR-ACC900

COR-ACC900

G

Abnormal

Single Tag

RF Learn Function 

Access programming 

mode 

 

*123456#   or  

*Master Code#   

(If already changed)

19*UUUUU*QQQQQ# 

UUUUU=5-digit User 

Address: 00000~01023

QQQQQ: Input 00001

 (Only one tag)

(i.e. 19*00001*00001)

Close Tag into RF Area

Present the tag to the 

controller.

OK 

(Memory location 

number)

Random Tag NO.

Access programming 

mode  

*123456#   or  

*Master Code# 

(If already changed)

 19*UUUUU*QQQQQ# 

UUUUU=5-digit User 

Address:00000~01023

QQQQQ: Input 00001  

Close Tag into RF Area

Present the tag to the 

controller.

OK 

(Memory location number)

The First tag has now been

added, present the rest of 

the tags one after the other

to add them to the system 

as well.

Sequential Tag NO.

Access programming 

mode

  

*123456#    or  

*Master Code#  

(If already changed)

 

19*UUUUU*QQQQQ# 

UUUUU=5-digit User 

Address: 00000~01023

QQQQQ: Input 5-digit tag 

units: Enter the 

quantity

 

of  tags

 to be added.  

(i.e.: 10 pcs of sequential 

tag=00010)  

Close Tag into RF Area

Present the tag with the 

lowest number

 to the 

controller.

OK 

(Memory location number)

A Batch of Tags

Adding Tag (M4/M8)

Deleting Tag (M4/M8)

Single Tag

Memory Location

A Batch of Tags

Memory Location

Delete All Tags

Access programming 

mode  

*123456#  or  

*Master Code# 

(If already changed)

 

10*SSSSS9EEEEE# 

9=Delete

SSSSS=starting user 

address

EEEEE=ending user 

address

(i.e. Delete User Address 

00003=10*00003900003)

Done

Access programming 

mode  

*123456#  or  *Master Code# 

 (If already changed)

 10*SSSSS9EEEEE# 

9=Delete

SSSSS=starting user 

address

EEEEE=ending user 

address

(i.e. Delete User Address: 

00004~00010=10*00004900010)

Done

Access programming 

mode  

*123456#  or  

*Master Code# 

(If already changed)

 

29*29*# 

Done

M4/M8 (Default Value: M4)

Deleting Tag (M6)

M6

Access programming 

mode  

*123456#    or  

*Master Code# 

(If already changed)

 

11*SSSSS*EEEEE# 

SSSSS

=starting user 

address=5-digit card code

EEEEE

=ending user 

address=5-digit card code

(i.e. Add a tag with card 

code 15031=

11*15031*15031)

(i.e. Add a batch of tag 

with card code 

15031~15038=

11*15031*15038)

Done

Access programming

mode  

*123456#    or  

*Master Code# 

(If already changed)

 

10*SSSSS*EEEEE# 

or

 

10*SSSSS9EEEEE# 

SSSSS

=starting user 

address=5-digit card code

EEEEE

=ending user 

address=5-digit card code

(i.e. Delete a tag with card 

code 15031=

11*15031*15031)

(i.e. Delete a batch of tag 

with card code 

15031~15038=

11*15031*15038)

Done

Access programming 

mode  

*123456#   or  

*Master Code# 

(If already changed)

 

29*29*# 

Done

Adding Tag (M6)

Delete Single/A Batch Tag

Delete All Tag

Enable: Access programming mode 

→ press  

* * 

Disable: Access programming mode 

→ press  * # 

Enable/Disable: Flash card + 
press 4 digit arming PWD  PPPP# 
 (default: 1234)

By Keypad

By flashing card + Arming PWD

Q: How to enable/disable the arming status?
A: 

02

03

06

05

28

To set how long the door relay (lock release) is active after presenting a card. 

Range: 0 ~ 600 (sec.); 601~609 (0.1~0.9 second)

To set value “0” will make door remain opening till card presented again, then door close. (Default value: 7 sec.)
To set how long the door contact can remain opening before activating the alarm.(Default value: 15 sec.)
When an alarm condition has arisen, the alarm will activate for this duration. Range: 1 ~ 600 (sec.) 

To set value “0” will make alarm relay keep on until disarming, then alarm relay off. (Default value: 7 sec.)
To delay the activation of the alarm relay after an alarm condition has arisen, so that user can have enough time 

 to disable alarm.  (Default value: 1 sec.)
To delay the time of enabling arming, so that user can have enough time to disable arming.  

Range: 1 ~ 600 (sec.)  (Default value: 1 sec.)
Activate the alarm immediately w/o having any alarm delay TM

Command

18

Adding and Deleting Tag

V150911

Содержание COR-ACC900

Страница 1: ...e Orange Purple Grey Thick Red Thick Black N C N O RS232 RS 485 or USB RS 485 Converter MagneticDoorContacts Magnet Lock Bolt Lock PushButton StrikeLock Contact Rating 1A125VAC 24VDC Do not connect the reader and lock to the same power supply Lock activation may cause reader power instability and might affect the reader function The door relay and the lock use the same power supply when applying a...

Страница 2: ...address EEEEE Ending user address 11 SSSSS EEEEE SSSSS Starting user address EEEEE Ending user address 12 UUUUU PPPP UUUUU User address PPPP 4 digit individual PWD 13 UUUUU PPPP UUUUU User address PPPP 4 digit individual PWD 14 TTT Arming output time 001 250 1 250 sec 15 PPPP PPPP 4 digit individual PWD P S Duress code will be unavailable and become a public PIN at access mode Card or PIN of M6 16...

Страница 3: ...00001 and PWD 1234 input 12 00001 1234 2 Changing the Master Code Access programming mode 123456 or Master Code If already changed 09 PPPPPPRRRRRR Input the 6 digit new master code twice 3 Changing the Node ID of Reader Access programming mode 123456 or Master Code If already changed 00 NNN Node ID 001 254 b Card and PIN Access programming mode 123456 or Master Code If already changed 13 UUUUU PPP...

Страница 4: ...eting Tag M6 M6 Accessprogramming mode 123456 or MasterCode Ifalreadychanged 11 SSSSS EEEEE SSSSS startinguser address 5 digitcardcode EEEEE endinguser address 5 digitcardcode i e Addatagwithcard code15031 11 15031 15031 i e Addabatchoftag withcardcode 15031 15038 11 15031 15038 Done Accessprogramming mode 123456 or MasterCode Ifalreadychanged 10 SSSSS EEEEE or 10 SSSSS9EEEEE SSSSS startinguser ad...

Отзывы: