CORONA  

BURNER CONTROLLER 

INSTRUCTION MANUAL 

RCF15 

EXCLUSIVE FOR FLAME ROD 

Corona Corporation 

Содержание RCF15

Страница 1: ...device and use the manual for quick reference when needed Reproduction of a part or all of the contents of this instruction manual without permission is prohibited The contents of this instruction ma...

Страница 2: ...at operation start PRECAUTIONS FOR SAFETY i The following are important items for safe use Be sure to read them before installation and start of use INTRODUCTION FEATURES OF THE PRODUCT This instructi...

Страница 3: ...out of the rated specifications specified in the instruction manual of the product Otherwise failure or malfunction may occur Perform wiring of the product correctly according to the specified standar...

Страница 4: ...ition 4 1 sec 11 1 sec Flame detection threshold 15 1 sec 15 1 sec 250VA Terminal Alarm 75VA Page 9 Product Specifications AC100V 85 110 50 60 7VA Terminal Ignition transformer Power supply frequency...

Страница 5: ...ct 7 8 9 Contact failure may generate high frequency radio waves which may cause malfunction 10 2 Installation and Wiring Do not bundle the power cable or the high voltage cable of the ignition transf...

Страница 6: ...the reverse procedure of the above 3 Installation method of the subbase 1 2 Secure the subbase at the specified position with screws At this time be careful not to apply excessive force to the screws...

Страница 7: ...with the installation of the main body Fig 3 shows the terminal layout of the subbase Fig 5 shows an example of wiring connection with external devices Ensure that the wiring is correct and then plug...

Страница 8: ...applied to the terminal when the air pressure switch is turned on Operation in Circuit 1 RCF15 Operation in Circuit Burner motor stops Pilot valve OFF Main valve OFF Combustion Alarm indicator LED is...

Страница 9: ...ilot valve are set to ON simultaneously and the Combustion Alarm indicator LED illuminates The state becomes post ignition when a flame is detected during the ignition trial within 4 seconds The burne...

Страница 10: ...ition Failure in the above Item 3 When a false flame signal continues even after the prepurge timing When a false flame signal is issued during the prepurge and the signal continues beyond the prepurg...

Страница 11: ...tline Drawing 4 Fig 7 Fig 8 M3 5 Terminal screw 10 Pg9 15 5 Knock out hole for conduit 2 M4 Terminal screw 3 Pg11 19 4 Knock out hole for conduit Securing screw 112 Dimension required to remove the re...

Страница 12: ...e flame rod If the flame rod is normal the RCF15 main body is defective Please replace it 2 If the flame rod is defective replace it with a non defective one 9 When the pilot burner ignites check the...

Страница 13: ...ote The contents of this document are subject to change without notice Operation where ignition sparks are not stopped immediately but kept for a fixed period of time to make flames stable when the pi...