START-UP
- 27 -
COROB™ D600 - D700 - D800TX
5 START-UP
5.1 General warnings
Personnel in charge of these operations must wear the following personal protective
equipment.
DANGER
THIS EQUIPMENT MUST BE GROUNDED. Check the grounding of the power supply system before
connecting the machine.
Do not use extension cords to power the machine.
The computer and any other devices connected to the machine via a serial line or connected to the computer
itself must be powered via the auxiliary sockets.
Do not connect equipment other than computer, label printer or calibration scale to the machine auxiliary
sockets.
Do not use multisockets to connect other equipment to the same socket that powers the machine.
WARNING
Do not attempt to power the machine from a source having specifications other than those listed on the
identification plate.
The machine is isolated from the power supply line when the power plug is disconnected; it must therefore be
installed near an easily accessible mains socket outlet.
Do not use multisockets to connect other equipment to the machine auxiliary sockets.
The power supply of the equipment connected to the machine via serial port, like the computer, must be
equipotential (which has a single access point to earth) because potential differences cause interferences and/
or damage to the serial ports.
Содержание D600 extra