X75 Fusion Splicer
Splicing
4-6
Fusion
Pre-fusion and fusion of the fibers is performed after alignment.
Visual
Inspection
The fiber cladding has a smooth surface if the splice is good. The cores, however, are not
visible at the monitor. The bright line in the middle of the fiber is a result of the lens effect of
the fiber itself. The illustration below shows a good splice.
Automatic
Splice Loss
Estimation
The splice is analyzed after completion of the splicing operation. The splice is inspected for
enlargements or constrictions, as well as homogeneity and offset. In the event of a faulty
splice, “Bad splice, fuse again?” is displayed at the monitor and
re-fusing can be performed.
-
Re-fusing is started by pressing the
key.
If the splice looks fine, splice loss is calculated and displayed in dB. Splice loss estimation
provides accurate results if the following prerequisites have been fulfilled: