X75 Fusion Splicer
Troubleshooting and Maintenance
Operating Instructions
revision: 06/01
6-9
Bad splice - fuse again?
The actual splice loss
may still be OK under
certain circumstances.
Pre-fusion parameter values to
high.
Reduce pre-fusion current or
pre-fusion time. Time may not
be set too low.
Contaminated optical system.
Check the image at the moni-
tor for visible signs of contami-
nation with no fibers inserted.
Remove contamination and
coating residue from the pro-
tection glass of the optical sys-
tem (see »Cleaning and
Replacing the Protection
Glass« on page 6-15).
Splice Memory
Error Messages
No data available
The splice memory is empty.
Make sure that the splice
memory has been activated in
the parameter menu. To save a
displayed loss value acknowl-
edge with
.
Errors
Messages
during Printing
Printer not ready!
The printer connected to the
serial interface transmits incor-
rect control characters.
Check the baud rate at the
printer and the fusion splicer.
Make sure that the printer sup-
ports the XON/XOFF proto-
col, and the appropriate data
format (8 data bits, 1 stop bit,
no parity).
Error Message
Possible Cause
Remedy
Содержание X75 8000 Series
Страница 8: ......
Страница 18: ...Operating Instructions revision 06 01 X75 Fusion Splicer X75 Fusion Splicer Overview 1 8 ...
Страница 58: ...Operating Instructions revision 06 01 X75 Fusion Splicer Splicing 4 10 ...
Страница 76: ...Operating Instructions revision 06 01 X75 Fusion Splicer Troubleshooting and Maintenance 6 16 2 3 1 4 ...
Страница 82: ...Operating Instructions revision 06 01 X75 Fusion Splicer Supplements Changes Notices 7 2 ...
Страница 83: ...X75 Fusion Splicer Supplements Changes Notices Operating Instructions revision 06 01 7 3 ...
Страница 84: ...Operating Instructions revision 06 01 X75 Fusion Splicer Supplements Changes Notices 7 4 ...