Warranties 

Hardware Warranty 

Corning Optical Communications Wireless, Inc. (“Corning”)warrants to the original purchaser (“Customer”) that for the duration of 
the warranty period, one (1) year, commencing on the date of shipment of the Hardware, unless otherwise agreed in writing by 
Corning (the “Hardware Warranty Period”), the Hardware furnished by Corning shall be free in all material respects from defects in 
material and workmanship, and shall conform to the applicable portions of the Specifications, as defined below (the “Hardware 
Warranty”). If notified by Customer of any such defects in material or workmanship or nonconformity with applicable portions of 
the Specifications within the Hardware Warranty Period, Corning shall promptly, at its own election and expense, repair or replace 
any such Hardware proven to be defective under the terms of this Hardware Warranty. Such repair or replacement shall be 
Customer’s sole remedy and Corning’s sole obligation in the event this Hardware Warranty is invoked. If any components 
comprising a part of the Hardware are replaced or repaired during the Hardware Warranty Period, the Hardware Warranty Period 
for such repaired or replaced components shall extend to the longer of (i) the balance of the Hardware Warranty Period or (ii) three 
(3) months from the date of repair or replacement. For purposes of this Warranty, “Specifications” shall mean the specifications 
and performance standards of the Products as set forth in documents published by Corning and delivered to Customer which 
contain technical specifications or performance standards for the Products. 
If Customer invokes this Hardware Warranty, it shall notify Corning promptly of the claimed defect. Customer will allow Corning to 
inspect the Hardware at Customer’s location, or to return the Hardware to Corning’s closest repair facility. For Hardware returned 
to Corning’s repair facility, Customer shall be responsible for payment of all transportation and freight costs (including insurance) to 
Corning’s repair facility, and Corning shall be responsible for all transportation and freight costs (including insurance) incurred in 
connection with the shipment of such Hardware to other repair facilities of Corning and/or its return to Customer. 
Notwithstanding the foregoing, in no event will Corning be liable for damage to Products resulting from improper 
handling during or after shipment, misuse, neglect, improper installation, operation or repair (other than by authorized Corning 
personnel), alteration, accident, or for any other cause not attributable to defects in materials or workmanship on the part of 
Corning. Corning shall not reimburse or make any allowance to Customer for any labor charges incurred by Customer for 
replacement or repair of any goods unless such charges are authorized in advance in writing by Corning. 

Software Warranty 

Corning warrants to the original purchaser (“Customer”) that for the duration of the warranty period, one (1) year, commencing on 
the date of shipment of the Software, unless otherwise agreed in writing by Corning (the “Software Warranty Period”), the 
Software shall conform with, and perform the functions set forth in the Specifications, and shall be free from defects in material or 
workmanship (the “Software Warranty”). In the event the Software is proven to be defective under the terms of this Software 
Warranty, Corning shall correct such defects or failure and ensure that the Software conforms with, and performs the functions set 
forth in, the Specifications. Customer will allow Corning to inspect the Software at Customer’s location or to return it to Corning’s 
closest repair facility. Notwithstanding the foregoing, Corning shall have no obligation under the Software Warranty if the Software 
is modified or used with hardware or software not supplied or approved by Corning or if the Software is subject to abuse, improper 
installation or application, accident, electrical or environmental over-stress, negligence in use, storage, transportation or handling. 
Third-party software distributed with the Software may carry certain warranties which, to the maximum extent allowed by law, 
Corning hereby assigns, transfers and otherwise conveys to Customer, provided, however, that Corning itself provides no warranty 
of any kind, express, implied, statutory or otherwise, for any third-party software provided hereunder. 
Corning does not warrant any hardware, software or services not provided by Corning. 
This warranty is the only warranty made by corning and is in lieu of all other warranties, express or implied including, but not 
limited to, the implied warranties of merchantability and fitness for a particular purpose. Corning shall not be liable for any other 
damage including, but not limited to, indirect, special or consequential damages arising out of or in connection with furnishing of 
goods, parts and service hereunder, or the performance, use of, or inability to use the goods, parts and service. Corning sales 
agents or representatives are not authorized to make commitments on warranty returns. 

Returns 

above warranty, the following procedure shall be followed: 
1. Return authorization is to be received from Corning prior to returning any unit. Advise Corning of the model, serial number, and 
discrepancy. The unit may then be forwarded to Corning, transportation prepaid. Devices returned collect or without authorization 
may not be accepted. 
2. Prior to repair, Corning will advise the customer of our test results and any charges for repairing customer-caused problems or 
out-of-warranty conditions etc. 
3. Repaired products are warranted for the balance of the original warranty period, or at least 90 days from date of shipment. 

 

 

Содержание Everon 6000 v1.0

Страница 1: ...Everon 6000 v1 0 User Manual Corning Optical Communications www corning com...

Страница 2: ...User Manual v1 0 Everon 6000 v1 0 User Manual...

Страница 3: ...ation of Corning and may not be reproduced in any form without the prior written consent of Corning No part of this document may be reproduced translated stored in a retrieval system or transmitted in...

Страница 4: ...pose other than originally designated for or stipulated by Corning Conventions Important information is highlighted in a frame as explained below Warning Actions requiring special attention to avoid s...

Страница 5: ...labor charges incurred by Customer for replacement or repair of any goods unless such charges are authorized in advance in writing by Corning Software Warranty Corning warrants to the original purcha...

Страница 6: ...e as far as reasonably free from danger Where there is a risk of damage to electrical systems involving adverse weather extreme temperatures wet corrosive or dirty conditions flammable or explosive at...

Страница 7: ...on safety levels and non environmental pollution during operation Compliance with RF Safety Requirements CAUTION Use of controls adjustments or performance of procedures other than those specified her...

Страница 8: ...l DC supply cable with connector Warning Always keep DC IN connectors connected during the product operation Company Certification Corning products have met the approvals of the following certifying o...

Страница 9: ...User Manual v1 0 UM Everon 6000 DAS 14 APR 2021 clear of comments docx March 2021 Page 9 of 202...

Страница 10: ...e VARs listed as licensed installers for Corning For the list of licensed VARs please contact the Technical Support Team at onesupport corning com or 1 833 4CORNING 833 426 7646 About This Manual This...

Страница 11: ...M Everon 6000 DAS 14 APR 2021 clear of comments docx March 2021 Page 11 of 202 Revision History Revision Date Created by Reviewed by Changes 0 1 Mar 2021 Yoni Henya Aloomit Godfarb Gila Shmueli Moti S...

Страница 12: ...0 2 2 2 IHU Interfaces and Slots 33 2 2 3 Mount the Chassis in a Rack 34 2 2 4 Install the Modules in the Chassis 35 2 2 5 Connect the Cables 36 2 2 6 Power ON 40 2 2 7 Verify NORNAL Operation 41 2 3...

Страница 13: ...n Rack 80 2 7 4 Wall Mount 81 2 7 5 Ground MRU Chassis 83 2 7 6 Connect Fiber SFP 84 2 7 7 Connect Antenna 85 2 7 8 External RF Source 3 5 GHz 85 2 7 9 Connect Power POWER UP 86 2 7 10 Verify Normal O...

Страница 14: ...reen Element Management 134 6 1 2 Events Screen 152 6 1 3 Admin Screen 153 6 1 4 Multi Stack Screen 166 6 1 5 Channels Screen 167 7 SNMP Management 174 7 1 SNMP Setup 175 7 1 1 Set Protocol Version Pa...

Страница 15: ...m per band to 43 dBm per band Advanced network configuration and management capabilities enable on site as well as remote end to end configuration system diagnostics maintenance and support operators...

Страница 16: ...iatio n Description Picture Chassis HEU Headend unit IHU Integrated headend unit Chassis modules RIM Radio interface module OIM Optical interface module HCM Headend control module ACM Auxiliary contro...

Страница 17: ...docx March 2021 Page 17 of 202 Abbreviatio n Description Picture Remote units LRU Remote Antenna Unit Medium Band Low Band MRU Mid power remote unit HRU High power Remote Unit NOC Network Operation C...

Страница 18: ...Core EUTRA Evolved Universal Terrestrial Radio Access EUTRAN Evolved Universal Terrestrial Radio Access Network FPGA Field Programmable Gate Array GE GigE Gigabit Ethernet GPS Global Positioning Syste...

Страница 19: ...lear of comments docx March 2021 Page 19 of 202 Abbreviatio n Description Picture UTRAN Universal Terrestrial Radio Access Network UDP User Datagram Protocol 1 3 Applicable Documents Table 2 Reference...

Страница 20: ...ll connected system devices using both web GUI HTTP and SNMP interfaces Note The HCM is installed in one headend element HEU or IHU an auxiliary control module ACM is installed in every additional HEU...

Страница 21: ...RI links each DRU has 32 ports The picture below presents a SISO configuration with 16 SISO MRUs connected to a single DRU HCM 1 ACM 1 DCM 1 DRU 1 1 2 3 4 1 2 3 4 1 2 3 4 29 30 31 32 DCM 2 1 2 3 4 SIS...

Страница 22: ...30 31 32 DRU 7 1 2 3 4 1 2 3 4 29 30 31 32 DRU 8 1 2 3 4 1 2 3 4 29 30 31 32 DCM 1 DRU 1 1 2 3 4 1 2 3 4 1 2 3 4 29 30 31 32 DCM 2 1 2 3 4 Medium band DRAU 1 MIMO A B Low band DRAU 1 MIMO A B 1 2 3 1...

Страница 23: ...sed for representing the RF signals Each DCM may convert signals capturing up to 190 MHz aggregated bandwidth RIX Radio Interface Expander combines downlink signals of the HEU and IHU RIMS and provide...

Страница 24: ...The LRU cooling is natural convection with no fans Due to its IP66 enclosure design the LRU can also be installed outdoors Remotes Up to 32 MIMO low power units per DRU when LRU low band with a single...

Страница 25: ...service module and native support of 2x2 MIMO antenna scheme The HRU modular structure enables set ups of up to 8 service modules in 600 700 MHz Low 700 MHz High FirstNet 800 850 MHz EAWS PCS WCS and...

Страница 26: ...tem Installation This chapter provides installation instructions for the system units Refer to the specific elements required in your deployment Head End HEU HIU see 2 1 DRU see 2 5 Remote units Insta...

Страница 27: ...le Installation Diagram Note Release 1 4 does not support combined connection between MRU and the other remote types Thus connect MRUs to a seperate DRU Remotes connected to DRU combination of all rem...

Страница 28: ...air of IHU HEU where the DCMs for the 2nd pair will be connected to the same DRU To support 4x4 configuration there is a need to add 2 additional pairs of IHU HEU and DRUs and remote units 2 for 4x4 s...

Страница 29: ...connection See 2 1 for example rack installations SISO MIMO IHU Expansion Connections TO IHU HEU and DRU Units A single IHU supports expansion connections as follows To one additional IHU unit To 7 HE...

Страница 30: ...Image HARDWARE provided in the box Headend Unit Chassis with blank panels on RIM and one PSM slots includes factory installed Fan Module FAM in chassis rear 1 FAM Fan Module FAM single unit hosting 4...

Страница 31: ...ngths ERFC16 L 16 in ERFC24 L 24 in ERFC34 L 34 in ERFC40 L 40 in ERFC59 L 59 in 1 DCM kit Optical cables Up to 900 meters LC UPC SM DX SFP Pluggable Transceivers hot pluggable optical transceiver mod...

Страница 32: ...Headend Control Module installed in Main HEU unit enables remote local management of all hosted units x ACM Kit Auxiliary Control Module installed in Auxiliary HEU units provides management connectio...

Страница 33: ...in the HEU Each IHU includes 14 slots supporting the following modules see Figure 4 IHU Interfaces and Slots Remove blank panel and slide in the relevant module chassis slots are 100 mistake proof 1...

Страница 34: ...ile considering additional HEU and IHU units and the lengths of the available ERFC cable 2 Refer to Error Reference source not found for an example planning the rack positions 3 Secure the units rack...

Страница 35: ...Captive Screws and Ejectors below that shows an example of module type captive screws and ejectors 2 2 4 1 Install the DCM Module 1 Slide the DCM to its slot in the HEU chassis Refer to 2 6 2 for mod...

Страница 36: ...IM connect the external RF source to the corresponding RIM service specific Simplex or Duplex QMA connectors a For each RIM connect the RF coax cable to the RIM s Simplex or Duplex QMA connectors b Ro...

Страница 37: ...t the REF OUT and REF IN ports of each of the RIX modules in the HEU chassis See Error Reference source not found Note use SFP from the approved list provided by Corning 1 Remove the rubber stopper fr...

Страница 38: ...ns to up to two IHU 1 Using the appropriate length ERFC cable according to distance of available OIX port connect the HEU RIX module 9 Pin connector to the corresponding connector on the IHU OIX modul...

Страница 39: ...rate LAN HCM LOCAL Port to ACM Port LOCAL Management Connection x HCM to ACM Management Connections using RJ45 RJ45 communication cables perform the headend management connections according to the fol...

Страница 40: ...C modules connect supplied power cable 100 240 VAC connector to the PSM input connector and to the AC outlet and switch on For PSM DC modules refer to Quick Start Guide provided with module for wiring...

Страница 41: ...v1 0 UM Everon 6000 DAS 14 APR 2021 clear of comments docx March 2021 Page 41 of 202 2 2 7 Verify NORNAL Operation If RF source is operational verify that the RIM DCM and HCM ACM LEDs indicate normal...

Страница 42: ...4 HEU supports the following expansion connection options To a single 7 IHUs Example of system connection The following figures describe an example rack installation for a maximum 4x4 HEU IHU configur...

Страница 43: ...following table Notes for details refer to APPENDIX B Ordering information see an example of package unpacking underneeth the table Table 4 HEU Package Items List Item Quantity Image HARDWARE provided...

Страница 44: ...onal lengths can be ordered PCKC20 L 20 in PCKC63 L 63 in PCKC79 L 79 in 1 ERFC Expander Cable RF interface cable to HEU 9 pin SMP to SMP connector Available in five different lengths ERFC16 L 16 in E...

Страница 45: ...r x dHCM Kit Headend Control Module installed in Main HEU unit enables remote local management of all hosted units x ACM Kit Auxiliary Control Module installed in Auxiliary HEU units provides manageme...

Страница 46: ...provided 1 Determine the location of the HEU in the rack while considering additional HEU and IHU units and the lengths of the available ERFC cable see Error Reference source not found for an example...

Страница 47: ...ule type captive screws and ejectors Refer to the Figure 7 HEU Slots and Interfaces for module locations Remove blank panel and slide in the relevant module chassis slots are 100 mistake proof One HCM...

Страница 48: ...anded copper wire conductors 10 14 AWG Holes 1 4 inch Grounding Lug Chassis Rear 2 3 4 2 Connect RIMS TO RF Source S For each RIM connect the external RF source to the corresponding RIM service specif...

Страница 49: ...2 Refer to TBD for schematic diagram of coax connections in a maximum HEU OIU configuration of 4x4 where all HEU units are connected to all IHU units 2 3 4 4 RIX Pilot Clock Connections Referring to t...

Страница 50: ...g to the following x Referring to the above Figure for configurations with one HCM and up to four ACM modules e g one HEU and four HIU units directly connect as follows From any HCM To any ACM INTERNA...

Страница 51: ...v1 0 UM Everon 6000 DAS 14 APR 2021 clear of comments docx March 2021 Page 51 of 202 2 3 6 Verify NORNAL Operation If RF source is operational verify that the RIM DCM and HCM ACM LEDs indicate normal...

Страница 52: ...rs as follows Connections to additional IHU unit IHU 1 RIX 9 Pin connector to the corresponding IHU 2 OIX module IHU 1 OIX 9 Pin connector to the corresponding IHU 2 RIX module Connections to addition...

Страница 53: ...Quantity Image Part Number HARDWARE provided in the box DRU unit 1 703A045402 AC Power Cord 708A042301 DC Power Adapter 255760003 HARDWARE not provided Screws Washers 4 4 NA SFP Pluggable Transceiver...

Страница 54: ...mini USB cable Note for technical support usage only NA Required Tools Screwdriver NA 2 5 2 DRU Interfaces The following images indicate the DRU interfaces Front view Back view Side view 2 RJ45 LAN fo...

Страница 55: ...nual v1 0 UM Everon 6000 DAS 14 APR 2021 clear of comments docx March 2021 Page 55 of 202 2 5 3 DRU Dimensions mm Attribute Description Height 1U 44 45 mm Width 19 482 6 mm Depth 16 5 419 mm Weight 9...

Страница 56: ...chassis rear Ensure the module is flush with the chassis rear Ensure at least 2 distance between the ventilation openings in the rear and sides of the DRU and any object e g wall 4 Secure the unit s r...

Страница 57: ...m the end of the SFP cable 5 Plug the LC UPC SM DX cable into the DCM port until it clicks 6 connect the other edge of the cable to the source unit Figure 9 Remove rubber stopper from port and from SF...

Страница 58: ...escribes each port the right pair relates to the upper slot the left pair relates to the lower slot Behaviour Right orange LED is lit during identification and when inserting the connector Left green...

Страница 59: ...pair of LEDs Orange Green describes each port the right pair relates to the upper slot the left pair relates to the lower slot Behaviour Right orange LED is lit during identification and when inserti...

Страница 60: ...owing table Table 5 LRU Package Items List Item Quantity Image Part Number HARDWARE provided in the box LRU unit 1 LRU 678 supporting low bands in MIMO configuration 600 700 and 800 850 LRU 17192325 s...

Страница 61: ...RF Jumper cables PN DC Power Adapter 255760003 HARDWARE not provided 4 screws 8 or 4mm for attachment to ceiling 4 SFP Pluggable Transceivers hot pluggable optical transceiver module Support for optio...

Страница 62: ...v1 0 UM Everon 6000 DAS 14 APR 2021 clear of comments docx March 2021 Page 62 of 202 2 6 2 LRU Dimensions mm Physical Dimensions Dimension W x H x D Inch mm 9 84 x 10 63 x 2 75 250 x 270 x70 Weight L...

Страница 63: ...0 UM Everon 6000 DAS 14 APR 2021 clear of comments docx March 2021 Page 63 of 202 2 6 3 LRU Interfaces Connectors CPRI Port 1 SFP 10 1Gbps Antenna Ports 2 4 3 10 female Antenna Ground Power SFP Manag...

Страница 64: ...al of 6 input ports and 2 output ports Notes 1 To avoid MIMO disruption ensure the antennas are connected correctly according to the combiner labels 2 There may be some configurations use cases where...

Страница 65: ...r Connection Interfaces Diagram The combiner connects between units Mid band LRU Low band LRU In the future High band CBRS LRU The antennas are MIMO1 MIMO2 2 6 5 Fully connected system diagram The fol...

Страница 66: ...02 2 6 6 Connect under lid cables For each of the units open the cover by removing 4 screws For each of the units connect the internal under cover cables as follows Power See 2 6 6 1Error Reference so...

Страница 67: ...minal block connector 2 6 6 2 SFP Cables Remove the rubber stopper from the SFP connector located in the LRU RF port Connect the SFP LC UPC SM DX optic cable to the LRU optic connector Figure 10 Remov...

Страница 68: ...guration relevant to your deployment Note For dual unit installations the internal RF connections must be connected before connecting between the units 2 6 7 1 Mount on a wall Note for the rear cases...

Страница 69: ...g 4 screws Connect between the low band and mid band units using the side bracket Note Ensure the low band device is connected at the bottom and the mid band on top Connect between the two devices and...

Страница 70: ...llation requirements The provided grounding lug supports 14 AWG to 10 AWG stranded copper or 12 AWG to 10 AWG solid wire conductors 1 Use a wire stripping tool to remove approximately 0 4 inch 10 9 mm...

Страница 71: ...3 10 Type duplexed RF ANTENNA port to the broadband antenna s using appropriate coax cables Notes 1 To avoid MIMO disruption ensure the antennas are connected correctly according to the combiner label...

Страница 72: ...1 clear of comments docx March 2021 Page 72 of 202 2 6 9 Combiner cables Connect the Antenna cables according to the figure below NOTE C Band is for future use Combiner in bracket Combiner Mid band Lo...

Страница 73: ...Page 73 of 202 Notes 1 To avoid MIMO disruption ensure the antennas are connected correctly according to the combiner labels 2 There may be some configurations use cases where a combiner is not requir...

Страница 74: ...User Manual v1 0 UM Everon 6000 DAS 14 APR 2021 clear of comments docx March 2021 Page 74 of 202 2 6 10 Verify normal operation The following table describes the LRU LED behaviour...

Страница 75: ...le according to the following table Notes for details see APPENDIX B Ordering information See unpacking example underneeth the table Table 6 MRU Package Items List Item Description Flavor PN Image Mid...

Страница 76: ...d DC power supply dMRU ASM DC dMRU DC supported assembly with three dPAM modules 600 700 AWS and PCS dMRU 671719 DC dMRU DC supported assembly with three dPAM modules 600 700 PCS and WCS dMRU 671923 D...

Страница 77: ...uantity 11 1 BR dMRU W DC connector class 1 mating 1 Not provided AC Power Cable AC models only Cable power straight U S 10 A UL L 1 8 2 5m black 110 V 1 SFP Pluggable Transceivers hot pluggable optic...

Страница 78: ...78 of 202 Example Package Unpacking For an ordered package of PN dMRU ASM AC Open the box and verify the following units are available DOPTM FAM Mid Plane Cavity Filter MUX and AC power supply The uni...

Страница 79: ...ule without first releasing may cause damage Corning will not be liable for damage of products resulting from improper handling during installation or repair PAMs are entered to their relevant slots b...

Страница 80: ...rding to the color codes 2 Determine the location of the MRU in the rack while considering additional units e g power supply 3 Referring to Figure 11 secure the units rack ears to the rack frame as fo...

Страница 81: ...ure to first press the release button on the module and then pull out using the handle see Error Reference source not found Any attempt to pull out the module without first releasing may cause damage...

Страница 82: ...PR 2021 clear of comments docx March 2021 Page 82 of 202 2 Assemble the wall mount bracket to MRU underside 3 Insert anchors in wall hang unit and tighten to secure Figure 13 Example of MRU Chassis wa...

Страница 83: ...the grounding wire depends on the proximity of the switch to proper grounding facilities Phillips head screwdriver Crimping tool to crimp the grounding wire to the grounding lug Wire stripping tool to...

Страница 84: ...it clicks note that there is only one correct direction for plugging in 3 Remove the white plug protectors from the end of the SFP cable 4 Plug the SFP cable into the D MRU port until it clicks 5 conn...

Страница 85: ...propriate coax cables Note The test port is used for coupling used for measuring the power without disconnecting the antenna 2 7 8 External RF Source 3 5 GHz The MRU includes one N Type Female RF port...

Страница 86: ...lation must be intact The cable must be firmly connected to both the electrical plug and the unit itself Standard plug the use of a standard plug is mandatory The use of a non standard power plug can...

Страница 87: ...36 60VDC Power consumption 580W maximum Maximum DC current consumption 16A 1 Open PSM captive screws and pull out module from chassis 2 Set DC input source type to CLASS1 connector and secure PSM modu...

Страница 88: ...Page 88 of 202 2 7 10Verify Normal Operation LEDs 1 Verify that fans are operational 2 Refer to status LEDs on the top left of the chassis door and on each PAM to confirm normal system operation acco...

Страница 89: ...User Manual v1 0 UM Everon 6000 DAS 14 APR 2021 clear of comments docx March 2021 Page 89 of 202 Table 9 SFP LEDs...

Страница 90: ...HRU Installation dHRU comes in various formats according to customer needs An example is brought bellow To install the dHRU follow these steps 1 Verify your box contents according to the specific mode...

Страница 91: ...IX B Ordering information See unpacking example underneeth the table Table 10 dHRU Package Items List Item Description Flavor PN Image dHRU dHPOM HRU Digital High Power Optical Module dHRU dHPAM 6 HRU...

Страница 92: ...pporting WCS dHRU dHPAM 25 HRU Digital High Power Amplifier Module supporting TDD 2500 100MHz contiguous BW dHRU COMB L HRU combiner module supporting low bands 600 700 800 850 including cables dHRU C...

Страница 93: ...em internal and external interfaces OEU interfaces see 2 8 2 1 RFU interfaces see 2 8 2 2 Fully connected system interfaces see 2 8 2 3 System connection architecture see 2 8 2 4 2 8 2 1 OEU interface...

Страница 94: ...cx March 2021 Page 94 of 202 OEU Dimensions 2 8 2 2 RFU Interfaces Bottom Panel Top Panel Local debug port RJ45 LED CPRI Optical Interface To OEU AC power from OEU Coupling power check without disconn...

Страница 95: ...User Manual v1 0 UM Everon 6000 DAS 14 APR 2021 clear of comments docx March 2021 Page 95 of 202 Mechanical dimensions...

Страница 96: ...02 2 8 2 3 Full System Interfaces The system includes two combiners and several band modules Note There are labels on the combiners indicating the RFU band names to which they connect two of each as t...

Страница 97: ...User Manual v1 0 UM Everon 6000 DAS 14 APR 2021 clear of comments docx March 2021 Page 97 of 202...

Страница 98: ...ystem internal and external interfaces The system includes two combiners 1 Low band Ports for 600 700 850 a port that that receives the combined RF signal from the mid band combiner entry coming from...

Страница 99: ...Page 99 of 202 2 8 3 Installation steps Overview 1 Mount the system see 2 8 3 1 2 Connect the internal cables CPRIs RFs see 2 8 3 2 3 Connect external cables OEUs to DRUs see 2 8 3 3 4 Connect the ot...

Страница 100: ...ct the modules to the bracket using screws as follows 1 Before mounting the dHRU unwrap each of the elements 2 Determine the location of the dHRU on the wall while considering accessibility 3 Connect...