Hardware Installation
BB-48 Control Panel Enclosure
Frame/Door Assembly
The Control Panel(s) hinged Frame/Door assembly is reversible, and can be mounted on either the left or right
side of the Back Box. The reversible Frame/Door assembly can be adjusted up to approximately 1” away from
the face of the chassis surface.
BB-49 Expansion Switch Enclosure Installation
The Expansion Switch enclosure is a surface mount, 16 gauge, primed and painted steel box, with an attached
hinged door assembly.
#7330-121 Enclosure Chassis: 4.0”
15.00”
18.00”
15Lbs
Installation Cont.
1. Position the Door/Frame assembly into
the back box accordingly.
2. Insert (2) of the 4 X 5/8” SS screws into
the hinge side of the Door/Frame
assembly. Do not over-tighten.
3. Insert the remaining (4) screws and
adjust the frame to align with the door,
when the door is closed.
Caution
Over-tightening the screws will warp or
bend the Door/Frame assembly and may
cause the hinge to operate improperly.
Installation Cont.
1. Surface mount the BB-49 using the
keyhole slots provided.
2. Mount the Expansion Switch using
(4) of the 10-32 Lock-Nut hardware
that is provided. Ensure the field
wiring moves freely and is not pinched
behind the Expansion Switch, prior to
tightening.
3. Connect the field wiring according to
the wiring diagram on starting on page
12.
4. Ensure the EMI Filters are installed
on the 4800V Call Station connections.
See page 17 for details.