background image

 

 

 

 

 

 

 

 

 

 

Control Panel 

1418 

– 2 – 151105  

 

Sensor 

 
OLET 17 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

314 SYOT 54 D     7014336      OT 2 PLE 

User and installation manual

 OT 2 PLE

 

 

 LAAVA

 

REWARD YOURSELF

 

Содержание OT 2 PLE

Страница 1: ...Control Panel 1418 2 151105 Sensor OLET 17 314 SYOT 54 D 7014336 OT 2 PLE User and installation manual OT 2 PLE LAAVA REWARD YOURSELF ...

Страница 2: ...ion IP X4 and may be mounted in the damp area outside the sauna room The control panel may not be installed inside the sauna room The sensor is installed in horizontal position at a distance of 40 mm from the roof on the centerline of the heater The installation and connection of the sauna heater control panel or any other electrical appliances may be done only by a licensed electrician in accorda...

Страница 3: ...he setting Once the operating time has been set the control unit will heat the sauna for the established time and once this time has expired the control unit will automatically switch itself off The LED light located next to the operating button will remain lit whenever an operating time has been set The operating time can be adjusted anywhere between 0 and 6 hours in 10 minute increments In profe...

Страница 4: ...nt D mm Floor K mm 3 0 4 5 6 0 8 0 9 0 2 4 3 6 5 9 8 13 9 14 1900 1900 1900 1900 1900 30 50 70 100 100 50 80 100 150 200 120 120 120 120 120 Heater Sauna room Min distances mm kW Volume m3 Height mm On side A mm In front D mm Floor K mm 3 0 4 5 6 0 8 0 9 0 2 5 3 6 5 9 7 12 8 13 1900 1900 1900 1900 1900 10 40 60 120 120 30 70 100 180 180 150 180 180 180 180 User and installation manual OT 2 PLE 4 m...

Страница 5: ...e A Cable H07RN F 60245 IEC 66 mm2 2 2 3 0 1 x10 1 x16 3 x 1 5 3 x 2 5 3 0 4 5 6 0 8 0 9 0 3 x 10 3 x 10 3 x 10 3 x 16 3 x 16 5 x 1 5 5 x 1 5 5 x 1 5 5 x 2 5 5 x 2 5 User and installation manual OT 2 PLE 5 K A A D min 20 min 30 min 20 min 30 F min 1900 mm mm 40 4 3 2 1 4 3 2 1 Terminal High limit Control panel 1 Blue 2 White 3 Red 4 Yellow 1 Blue 2 White 3 Red 4 Yellow Sensor cable Sensor connecti...

Страница 6: ... närmaste återvinningsplats Instructions for environmental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and electronic devices The symbol on the product the instruction manual or the package refers to this The materials can be recycled according to the marki...

Отзывы: