MINIMUM DISTANCE(mm) FOR HEATER:
1714 - ..
– 04
MINIMUM DISTANCE(mm) FOR HEATER:
1712 - .. - 04
MINIMUM DISTANCE(mm) FOR HEATER:
1720 - .. - 04
Heater
Sauna room
Min. distances (mm)
kW
Volume
m
3
Height
mm
On side
A
mm
In front
D
mm
Floor
K
mm
4,5
6,0
8,0
9,0
3
– 6
5
– 9
8
– 12
9
– 13
1900
1900
1900
1900
40
45
75
80
80
100
130
150
120
120
150
150
Heater
Sauna room
Min. distances (mm)
kW
Volume
m
3
Height
mm
On side
A
mm
In front
D
mm
Floor
K
mm
3,0
4,5
6,0
8,0
9,0
2
– 4
3
– 6
5
– 9
8
– 13
9
– 14
1900
1900
1900
1900
1900
30
50
70
100
100
50
80
100
150
200
120
120
120
120
120
Heater
Sauna room
Min. distances (mm)
kW
Volume
m
3
Height
mm
On side
A
mm
In front
D
mm
Floor
K
mm
3,0
4,5
6,0
8,0
9,0
2
– 5
3
– 6
5
– 9
7
– 12
8
– 13
1900
1900
1900
1900
1900
10
40
60
120
120
30
70
100
180
180
150
180
180
180
180
User and installation manual
OT 2 PLE
4
(mm)
min
30
min
20
min
20
K
A 475 A
min
30
5
0
5
m
in
1
1
0
0
m
in
1
9
0
0
300 D
40
238
K
A
A
D
m
in
2
0
min 30
m
in
2
0
min 30
F
m
in
1
9
0
0
(mm)
40
(mm)
K
A
A
D
mi
n
2
0
min 30
mi
n
2
0
min 30
1100
mi
n
1
9
0
0
(mm)
40
(mm)