UCR 700 Series Continuous Flow Icemaker Installation/Service Manual
© 2001-2012, IMI Cornelius Inc.
- 4 -
Publication Number: 630460154
S
PECIFICATION
C
HART
Water Supply--Water inlet fitting is 1/4--inch SAE flare located at the top front of the Unit. The Unit is designed to
operate on water pressure between 10 PSI and 90 PSI.
Drain Overflow Line (Located at rear of the Unit)
3/8--inch Flexible Tubing
Ambient Operating Temperature
40° F to 100° F
Electrical:
Unit Electrical Rating
115 VAC, 60 Hz, 15.6 Amps,
Single Phase
Recommended Electrical Supply
115 VAC, 60 hz, 20 Amps
Dedicated 3--Wire Grounded
Circuit
Models
Condensing
Unit
VAC
HZ
PH
Wire
Comp.
RLA
Fan
Amps
GRMTR
Amps
Refrigerant
Circuit
Fuse
Oz.
Type
UCR700--A
Air Cooled
115
60
1
2
12
1.6
2
24
R404A
20
UCR700--W
Water Cooled
115
60
1
2
12
N/A
2
13
R404A
20
Table 1. Design Date
Unit Model Number: