![Cornelius UCR 700 Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/cornelius/ucr-700-series/ucr-700-series_installation-and-service-manual_2668272011.webp)
UCR 700 Series Continuous Flow Icemaker Installation/ServiceManual
Publication Number: 630460154
- 7 -
© 2001-2012, IMI Cornelius Inc.
A. The plugs are pressed in and sealed with a silastic sealant. To remove pry the outside cap off and then
press the inside plug into the bin. Discard both plugs.
B. Install the icemaker alignment brackets (Supplied with icemaker) to the dispenser (See Figure 2).
5.
Install the Icemaker:
A. Install the icemaker alignment brackets (Supplied with icemaker) to the icemaker (See Figure 2).
B. Roll the Icemaker into the cabinet alongside the Dispenser.
C. Level and align the icemaker to the dispenser using the four level adjustment bolts located on the lower
front of the Icemaker.
D. Install the locking bolt on the lower front of the icemaker.
E. Connect drain, power and water.
6.
Install transport tube:
A. Insert the ice transport tube through the bin into the transport elbow on the Icemaker. (
Note:
The ice-
maker is equipped with a safety switch located at the base of the elbow, this switch will prevent the ice-
maker from running if the elbow is not properly installed).
B. Align the nylon lock screw on the elbow with the recess on the tube. Install lock screw.
7.
Connect bin thermostat:
A. Locate bin thermostat cable supplied with the icemaker (Black cable) and connect to electrical box on
the UCR700 and the receptacle on the side of the dispenser.
Figure 2. Side Bracket Installation
Attach
to
bin
Right
Side
Install
Attach
to
bin
Left
Side
Install