TO REPLACE WATER LEVEL CONTROL
1.
Shut off the water supply. Shut off the main power switch or unplug the ice dispenser from electrical outlet.
2.
Remove the flexible tubing from bottom of water level control and drain water from water level control and
evaporator.
3.
Remove flexible tubing at bottom of water level bowl connected to the overflow.
4.
Hold water inlet fitting with proper tool to prevent it from rotating when disconnecting the water inlet.
5.
Remove wing nut holding water control to its mounting bracket. Control can be removed by lifting straight
up.
TO REPLACE WATER LEVEL SAFETY SWITCH
1.
Shut off main power switch or unplug the ice dispenser from electrical outlet.
2.
Unplug molex connector connecting switch to electrical box.
3.
Remove the 2 screws anchoring the water level safety switch to the bottom of the water level control
mounting bracket.
R
EFRIGERATION
S
YSTEM
NOTE: Thermostatic Expansion Valve No Adjustment
±10 Lbs Discharge Pressure
WATER TEMPERATURE
R
EFRIGERATION
S
YSTEM
A
DJUSTMENTS
A complete understanding of the icemaker and hermetic refrigeration system is necessary before any adjustments
are made. The refrigeration technician must use high and low side pressure readings, water and air temperatures,
plus general conditions of cleanliness to assess the refrigeration system status when making any adjustments.
All icemaker products are tested and adjusted at the factory prior to shipment where the ambient temperature
ranges from 65_ to 90_F, depending on the season of the year.
Whenever a new icemaker product is initially installed and started-up, it is imperative that the start-up operation
make the following checks and/or readjustments for local conditions.
A
I
R
T
E
M
P
40°
65°
90°
50°
174
177
180
60°
202
205
208
70°
230
233
236
80°
265
269
272
90°
300
304
307
100°
328
334
340