Signature Service Manual
© 2011, IMI Cornelius Inc.
- 41 -
Publication Number: 621058426SER
Figure 58. E-Box Components for 120V Unit
C
OMPRESSOR
R
ELAY
R
EPLACEMENT
The compressor relay, shown in Figure 58, is mounted in the E-Box on the left side of
the unit. To replace a compressor relay, perform the procedure in Table 29.
C
ONTROL
K
EYPAD
R
EPLACEMENT
The Control keypad is a membrane switch panel that contains all of the switches controlling
the Signature unit. If the panel requires replacement, perform the procedure in Table 30.
Compressor
Contactor
Start & Run
Capacitors
(Compressor)
Step Down
Transformer
(Hi Volt/24VAC)
24 VAC Term.
Board
Compressor
Relay
High
Voltage
Term.
Board
Table 29.
Step
Procedure
1
Disconnect power from the unit.
2
Remove the left side cover and the E-Box cover.
3
Label and disconnect the wires from the defective relay.
4
Loosen the mounting screw holding the relay.
5
Replace the defective relay, observing the proper orientation of the relay.
6
Reverse the procedure to install the new relay.
7
Replace the E-Box cover and the left side panel.
8
Reconnect power to the unit.
Table 30.
Step
Procedure
1
Disconnect power from the unit.
2
Connect a static strap to your wrist and any convenient chassis ground on the unit.