Signature Service Manual
© 2011, IMI Cornelius Inc.
- 35 -
Publication Number: 621058426SER
Figure 51. View of Bottom Fan Mounting Bolts
C
OMPRESSOR
R
EPLACEMENT
!
WARNING:
Only trained and certified electrical, plumbing and refrigeration technicians should
service this unit.
ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL
CODES. FAILURE TO COMPLY COULD RESULT IN SERIOUS INJURY,
DEATH OR EQUIPMENT DAMAGE.
To replace a compressor, perform the procedure in Table 21.
NOTE: Be sure to reclaim refrigerant when replacing compressor.
Fan
Mounting
Bolts
Rear of Unit
Table 21.
Step
Procedure
1
Disconnect power to the unit.
2
Remove the side panels from the unit.
3
Label and disconnect all wires from the compressor.
4
Reclaim the refrigerant from the system.
5
Remove all insulation from around fittings.
6
Unsweat the suction and discharge lines from the compressor.
7
Remove the four (4) mounting bolts from the base of the compressor.
8
Remove the compressor.
9
Reverse the procedure to install the new compressor. (Tighten the 5/16-18 bolts to
132 in-lbs.)
10
Replace the dryer.
11
Replace all insulation around fittings.
12
Evacuate the system and recharge it according to the Cornelius nameplate on the
unit.
13
Replace the side panels.
14
Reconnect power to the unit and test the unit.
Содержание signature
Страница 53: ......