background image

3

569000264

5. Place product coils assembly back in position inside the Unit. Make sure ice bank control  capillary tube is

routed from ice bank control bulb  up along right front side (facing front of Unit) of the Unit and on up to the
ice bank control as shown in Figure 3.

6. Connect product tubes, connected to the product coils, to backs of the dispensing valves.

7. Place Unit product inlet fittings up through holes in the agitator motor assembly bracket and secure with

white plastic washers and hex nuts.

8. Place the agitator motor assembly bracket back into position on the Unit. Secure agitator motor assembly

bracket with six screws retained in step 12 of PREPARING DISPENSER FOR KIT INSTALLATION.

9. Connect product source product inlet lines to Unit product inlet lines fittings on the agitator motor assembly

bracket.

10. Place the new ICE BANK CONTROL (item 1) in approximate mounting  position on the agitator motor as-

sembly bracket as shown in Figure 3.

11. Install SNAP BUSHING (item 11) in hole in ICE BANK CONTROL BOX (item 2).

12. Connect BLACK ELECTRICAL WIRE (item 8) and RED ELECTRICAL WIRE (item 9) to terminals on the

ice bank control as shown in Figure 2.

13. Install ICE BANK CONTROL (item 1) inside the ICE BANK CONTROL BOX (item 2) and secure with

SCREWS (item 5).

14. Place ice bank control capillary tube in hole in the key-hole slot in the ice bank control box.

15. Install GROMMET (item 3) on the ice bank control capillary tube, then slide grommet up on the capillary

tube and install in key-hole slot in ice bank control box.

16. Route Unit wiring harness electrical wires in through snap bushing installed in the ice bank control box.

17. Connect Unit wiring harness green ground wire to ground lug inside the control box. Secure ground con-

nection with HEX NUT (item 14).

18. Complete remainder of wiring connections inside the ice bank control box by referring to Figure 4 Wiring

Diagram.

19. Place ice bank control in position on the agitator motor assembly bracket. Secure ice bank control to the

motor assembly bracket with SELF DRILLING SCREWS (item 10).

20. Very carefully, route capillary tube along Unit wiring harness as shown in Figure 3.

21. Using WIRE TIES (item 12), secure capillary tube to the Unit wiring harness as shown in Figure 3.

22. Install LABEL, HAZARD SHOCK (item 4) on ice bank control cover as shown in Figure 3.

23. Install handle on Unit and secure with screws.

RESTORING UNIT OPERATION

1. Fill water tank with water as instructed in manual provided with your Dispenser. USE LOW–MINERAL–

CONTENT WATER WHERE A LOCAL WATER PROBLEM EXIST.

2. The Unit product systems should be sanitized at this time. Refer to manual provided with your Dispenser

for sanitizing instructions.

3. Connect electrical power to the Unit.

4. Connect Unit product inlet lines to product tanks, then open each dispensing valve to bleed air from the

systems and until product is dispensed.

5. Check the Unit for product leaks and repair if evident.

6. Check Unit for proper operation, then close hinged top cover.

Содержание Remcor 2849949020

Страница 1: ... before installing this kit Retain these instructions as part of your equipment manual Table 1 Loose Shipped Parts Item No Part No Name Qty 1 315794000 Ice Bank Control White Rodgers 1 2 3528 Box Ice Bank Control 1 3 186125000 Grommet 1 4 313457000 Label Hazard Shock 1 5 187188000 Screw Machine No 8 32 X 250 2 6 3529 Holder Control Bulb 1 7 180024000 O Ring 2 8 3575 Electrical Wire Black 1 9 3576 ...

Страница 2: ...y bracket to the Unit then remove agita tor motor assembly bracket from the Unit 13 Disconnect product tubes from backs of the dispensing valves then lift product coils assembly up out of the Unit 14 Remove old ice bank control probe and ice bank control probe holder from the evaporator coil Retain old ice bank control probe and probe holder which are to be returned to IMI Cornelius INC 15 Remove ...

Страница 3: ...on the ice bank control capillary tube then slide grommet up on the capillary tube and install in key hole slot in ice bank control box 16 Route Unit wiring harness electrical wires in through snap bushing installed in the ice bank control box 17 Connect Unit wiring harness green ground wire to ground lug inside the control box Secure ground con nection with HEX NUT item 14 18 Complete remainder o...

Страница 4: ...NK CONTROL PROBE LOCATION ICE BANK CONTROL BULB Î Î Î NO 3 COIL 6 500 IN ICE BANK CONTROL ITEM 1 RED WIRE ITEM 9 BLACK WIRE ITEM 8 FIGURE 2 ICE BANK CONTROL O RING ITEM 7 O RING ITEM 7 ICE BANK CONTROL BULB CAPILLARY TUBE TO ICE BANK CONTROL ICE BANK CONTROL BULB HOLDER ITEM 6 ...

Страница 5: ...5 569000264 FIGURE 3 UNIT TOP VIEW ICE BANK CONTROL ASSEMBLY ITEMS 1 AND 2 AGITATOR MOTOR BRACKET UNIT WIRING HARNESS HAZARD SHOCK LABEL ITEM 4 CAPILLARY TUBE SNAP BUSHING ITEM 11 GROMMET ITEM 3 ...

Страница 6: ......

Страница 7: ...6 569000264 ICE BANK CONTROL BULB FIGURE 4 UNIT WIRING DIAGRAM ...

Отзывы: