DISPENSER INSTALLATION
The proper cuber/dispenser installation package should be ordered. This package will include gasket material
and hold-down bracket.
ELECTRICAL SERVICE LINE
MANUAL DISCONNECT SWITCH
STRAIN RELIEF
WATER FILTER
SHUT-OFF VALVE
DUMP VALVE
DRAIN TUBE
BIN DRAIN TUBE
FLOOR DRAIN
AEROQUIP VALVE FITTING
PLUMBING CONNECTIONS
1. All plumbing lines and connections must conform to local and national plumbing codes.
2. Line shut-off valves must be located in supply water lines for cuber and condenser if product is water-
cooled. Water supply to water-cooled condenser must include a stand-pipe to prevent “water hammer”.
3. Should your local water supply quality require the installation of a water filter system, consult your local dis-
tributor or dealer for proper size required.
4. Water supply pressure must not be lower than 20 PSI (1.37 BAR), nor should it exceed 120 PSI (8.16
BAR).
IMPORTANT: Water filters larger then 5 microns do not give proper protection. Water pressures above
80 PSI (5.44 BAR) will destroy the filter.
NOTE:
Bin and cuber drain lines must never be connected together and must be vented.