Countertop Icemaker IMD Series Installation Manual
© 2004-2012, IMI Cornelius Inc.
- 17 -
Publication Number: 638085277INS
The Motor Runs but Output Shaft does not Rotate
Replace defective gear motor.
CAUTION:
!
Be sure unit is disconnected from the power source. Disconnect the transmission cable.
O
VERLOAD
C
HECK
1.
Allow motor to cool and reset overload if necessary.
2.
Remove motor end bell and stator, if necessary.
3.
Check terminals 1 and 3 on overload. No continuity replace overload. Use a volt-ohm meter. See Figure 8 and
Figure 9.
NOTE: Gear motor and related components can be checked from Pin Connector. See Figure 12.
M
OTOR
C
HECK
The resistance readings on the windings will be between 5 to 25 ohms. A meter capable of these low readings must
be used. The Start Relay cover must be removed.
If no continuity on start or run winding test, replace stator. If continuity on grounded motor test, replace stator.
Figure 12. Pin Numbers.