Countertop Icemaker IMD Series Installation Manual
Publication Number: 638085277INS
- 8 -
© 2004-2012, IMI Cornelius Inc.
GUIDE TO SERVICE
I
CEMAKER
C
LEANING
AND
S
ANITIZING
P
ROCEDURES
Do not use any of the ice made during cleaning operations.
Clean and sanitize ice storage area when cleaning icemaker.
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
1.
Shut off water supply.
2.
Remove ice from storage bin.
3.
Mix approved cleaner (2 gallons as directed).
Recommended cleaner:
Calgon Corp. of Virginia Chemicals,
ice machine cleaner.
Mixture:
3-1/3 ounces per gallon of water. Do not use nickel safe cleaners.
4.
Turn machine on and add cleaner solution to water level control (float reservoir) until 2 gallons have been used.
5.
Turn on water supply and run machine for 15 minutes.
6.
Turn off machine and remove and discard all ice.
7.
Sanitize using household liquid bleach (50 ppm chlorine).
Mixture:
1 fluid ounce per gallon room temperature
water. 2 minute exposure time.
8.
Sanitize pre-cleaned inside areas of storage bin liner, door frame, door, as well as exposed surfaces of the
evaporator assembly and bin shutoff assembly with sanitizing solution and allow to air dry.
M
AINTENANCE
Preventive maintenance can increase the trouble free life of your icemaker. Many authorized service agencies offer
service contracts for your icemaker. Contact your local distributor for further information.
Monthly
1.
Clean the condenser. Use a brush, vacuum cleaner or blow from inside with air or CO
2
gas. If unit is provided
with and air filter, clean or replace.
2.
Inspect water feed reservoir at least once a month until a definite pattern for cleaning and sanitizing has been
established.
Quarterly
This is the maximum period of time between cleaning and sanitizing the icemaker. In addition to recommended
monthly procedure, and if a more frequent cleaning and sanitizing pattern has not been established, unit must be
cleaned and sanitized.
Содержание IMD300-15A
Страница 29: ......
Страница 30: ...IMI Cornelius Inc www cornelius com...