Cornelius IDC 2XX Скачать руководство пользователя страница 7

IDC Operator’s Manual

Publication Number: 621057403OPR

- 4 -

© 2005-2010, IMI Cornelius Inc.

CLEANING AND MAINTENANCE INSTRUCTIONS 

These instructions are used on all Cornelius ice drink dispensers.

Some models may have additional cleaning requirements. 

Those models will have addition procedures listed later in the manual.

!

WARNING:

Disconnect power to the unit before cleaning or servicing following all lock out / tag out procedures established by 
the user. Verify all of the power is off to the unit before performing any work. 

Failure to comply could result in serious injury, death or damage to the equipment.

CAUTION:

!

Do not use metal scrapers, sharp objects or abrasives on the ice storage hopper, top cover, agitator disc or 
exterior surfaces as damage to the unit may result. Do not use solvents or other cleaning agents as they may 
attack the material resulting in damage to the unit.

Soap solution

 – Use a mixture of mild detergent and warm (100° F ) potable water. 

Sanitizing Solution

 – Dissolve 2 packets (4 oz) of Stera Sheen Green Label into 2 gallons of warm (80 – 100° F) 

potable water to ensure 200 ppm of chlorine.

Daily Cleaning:

1.  Remove cup rest from drip tray and clean with warm soapy water, rinse with clean water and allow to air 

dry.

2. Wipe down the exterior of the unit with warm soapy water, rinse with clean water and allow to air dry. 

3. Remove valve nozzles and diffusers and wash in warm soapy water, rinse in clean water and allow to air 

dry. 

4. Clean the interior of the ice chute using the brush provided with the unit with warm soapy water, rinse 

with clean water and allow to air dry. 

5. Spray the ice chute inside and out with sanitizer and allow to air dry. 

6. Pour warm soapy water down the drains to keep them clean and flowing smoothly. 

7. Spray the nozzles and diffusers inside and outside with approved sanitizing solution, reinstall them on the 

valves and allow to air dry. 

8. Reinstall the cup rest into the drip tray. 

9. Pour all remaining sanitizer solution down the drains to help keep the drain clear. 

Daily Maintenance:

1.  Check the temperature, smell and taste of the product. 

2. Check the water pressure coming to the unit using the pressure gauges on the back room package. 

3. Check carbonation of the drink

4. Check level of CO2 supply to the system.

5. Check the date on all of the BIB’s (bags in boxes). 

Weekly Cleaning: (In addition to daily procedures) 

Remove the ice chute cover and clean it along with the back half with warm soapy using the brush provided with 
the unit. Rinse with clean water and reinstall on the unit. Spray the ice chute assembly with approved sanitizer 
allowing it to air dry. 

Содержание IDC 2XX

Страница 1: ...d Carbonation Operator s Manual Release Date October 18 2005 Publication Number 621057403OPR Revision Date August 3 2010 Revision F Visit the IMI Cornelius web site at www cornelius com for all your L...

Страница 2: ...rvice required by or loss or damage resulting from any of the following occurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Pr...

Страница 3: ...r on a Counter 2 Start up and Operating Instructions 3 Ice Drink Dispenser 3 Cleaning and Maintenance Instructions 4 Daily Cleaning 4 Daily Maintenance 4 Weekly Cleaning 4 Monthly Cleaning 5 Yearly Ma...

Страница 4: ...damage SAFETY TIPS Carefully read and follow all safety messages in this manual and safety signs on the unit Keep safety signs in good condition and replace missing or damaged items Learn how to oper...

Страница 5: ...residual sanitizing solution or water remaining inside the unit to freeze resulting in damage to internal components CO2 CARBON DIOXIDE WARNING DANGER CO2 displaces oxygen Strict attention MUST be ob...

Страница 6: ...chunks of ice which jam up inside the hopper will cause failure if the agitator motor and damage to the hopper If bagged ice is used it must be carefully and completely broken into small cube sized p...

Страница 7: ...water and allow to air dry 2 Wipe down the exterior of the unit with warm soapy water rinse with clean water and allow to air dry 3 Remove valve nozzles and diffusers and wash in warm soapy water rins...

Страница 8: ...ve agitator assembly 2 Using a nylon bristle brush or sponge clean the interior of the hopper top cover and agitator assembly with soap solution Thoroughly rinse the hopper cover and agitator surfaces...

Страница 9: ...rent product tube each time until all tubes are filled with the sani tizing solution 11 Remove the nozzle and syrup diffuser and clean them in a mild soap solution Rinse with clean water and reassembl...

Страница 10: ...o avoid personnel injury and or property damage always secure the CO2 cylinder with a safety chain to prevent it from falling over Should the valve become accidently damaged or broken off a CO2 regula...

Страница 11: ......

Страница 12: ...IMI Cornelius Inc www cornelius com...

Отзывы: