IDC 255 Progate Drive Thru Installation Manual
© 2022, Marmon Foodservice Technologies Inc.
- 9 -
Publication Number: 621057419INS
2. The beverage tubes, drain tube and power cord are routed through the large opening in the bottom of the unit. See the
MOUNTING TEMPLATE for locating the required clearance opening in the counter for these utility lines.
DRIP TRAY DRAIN ASSEMBLY:
Route the drain tube to an open drain with the end of the tube above the “flood” level of the
drain. Use the tubing, fittings, clamps, and insulation provided with the Dispenser to assemble the drain. The completed drain line
must
pitch continuously downward and contain no “traps” or improper drainage will result.
Figure 6.
NOTE: Cornelius Inc. recommends that a water shutoff valve and water filter be installed in the plain water
inlet supply line. A Cornelius Water Filter (P/N 313860000) and QUICK DISCONNECT SET (P/N 313867000)
are recommended.
CAUTION
:
!
Check the minimum flow rate and the maximum pressure of the plain water inlet supply line. MINIMUM FLOW RATE MUST
BE AT LEAST 125 GALLONS PER HOUR. If flow rate is less than 125 gallons per hour, starving of the carbonator water pump
will occur. Starving will overheat the carbonator’s water pump, causing the safety thermostat on the pump outlet to stop the water
pump motor. Overheating could occur if the plain water supply line flow rate drops below 125 gallons per hour. INCOMING
PLAIN WATER INLET SUPPLY LINE WATER TO PUMP PRESSURE MUST REMAIN A MINIMUM OF 10 psi BELOW
THE CARBONATED CO
2
OPERATING PRESSURE. (Example: The Carbonator CO
2
operating pressure is 75 psi and the
maximum water pressure can be no more than 65 psi, etc.). Static water pressure higher then the static CO
2
pressure can cause
carbonator flooding, malfunction, and leakage through the carbonator relief valve. If water is exceeding maximum pressure
specifications, a Water Pressure Regulator Kit must be installed in the plain water inlet supply line.
3. Cut power to the carbonator by turning off its power switch, the switch is located on the junction box of the pump and
motor assembly. Locate the carbonator pump assembly and connect to power cord from the Ice/Drink Unit to the pump.
The cord is connected to the unit’s electrical box and has an electrical connector on the end that plugs into a receptacle in
the junction box at the carbonator pump assembly. Connect inlet water to pump and pump outlet to Ice/Drink Unit using 3/
8-inch food-grade tubing.
4. Connect the beverage system product tubes as indicated in applicable Flow Diagram in this manual or on the back of the
splash panel. This work should be done by a qualified service person.
DRAIN LINE
1" I.D. PLASTIC TUBING
(6') WITH INSULATION
HOSE CLAMP