IDC 255 Progate Drive Thru Installation Manual
Publication Number: 621057419INS
- 8 -
© 2022, Marmon Foodservice Technologies Inc.
INSTALLATION
M
OUNTING
AND
P
LACEMENT
!
WARNING
:
It is the responsibility of the installer to ensure that the water supply to the dispensing equipment is provided with protection back
flow by an air gap as defined in ANSI A 112.1.2-1979; or an approved vacuum breaker or other such method as proved effective
by test and must comply with all federal, state and local codes.
Failure to comply could result in serious injury, death or damage to the equipment.
Water pipe connections and fixtures directly connected to a potable water supply
shall be sized, installed and maintained
according to Federal, State and Local
laws.
1. Locate the dispenser indoors on a level counter top.
A.
LEG OPTION
Unpack the four (4) legs and install them into the threaded holes provided at the bottom of the unit. The installer must
provide flexibility in the product and utility supply to permit shifting the position of the dispenser sufficiently to clean
the area beneath it.
COUNTER MOUNTING
The ice drink dispenser must be sealed to the counter. The template drawing indicates where openings can be cut in the counter.
Locate the desired position for the dispenser, then mark the outline dimensions on the counter using the template drawings. Cut
openings in counter.
Figure 5.
Apply a continuous bead of
NSF International
(NSF) silastic sealant (Dow 732 or equal) approximately
1/4-inch inside of the unit outline dimensions and around all openings. Then, position the unit on the counter within the outline
dimensions. All excess sealant must be wiped away immediately.
30
26 3/8
1 13/16
1 5/16
18 5/8
12
9
3 1/2
9 1/2
11
23
21 1/4
30
31 1/2
REMOVABLE SINK
RECOMMENDED COUNTER OPENING SIZE
9 X 12 FOR UTILITIES AND BEVERAGE
TUBING. OPENING CAN BE LOCATED
ANYWHERE WITHIN SHADED AREA.
7/16 DIA.
23 1/16
Z Style